Toyota Corolla Cross Owners & Service Manuals

Toyota Corolla Cross: No Warm Air Comes Out

DESCRIPTION

If cool air blows from the registers regardless of the temperature setting of the air conditioning system, the following factors may be the cause.

Symptom

Factor

  • No warm air comes out

    (Blower control is normal)

  • Outlet air temperature does not increase

    (Blower control is normal)

  • Engine coolant temperature (low)
  • Air mix damper and link operation (jamming)
  • Warm-up control
  • Blockage in heater radiator unit sub-assembly
  • Heater radiator unit sub-assembly malfunction

PROCEDURE

1.

READ VALUE USING GTS (COOLANT TEMPERATURE)

(a) Read the Data List according to the display on the GTS.

Powertrain > Engine > Data List

Tester Display

Measurement Item

Range

Normal Condition

Diagnostic Note

Coolant Temperature

Coolant temperature

Min.: -40°C (-40°F)

Max.: 140°C (284°F)

75 to 100°C (167 to 212°F): After warming up

This is the coolant temperature.

HINT:

  • After warming up the engine, the coolant temperature will be 75 to 100°C (167 to 212°F).
  • After a long soak, the coolant temperature, intake air temperature and ambient air temperature will be approximately equal.
  • If the value is -40°C (-40°F), or higher than 135°C (275°F), the sensor circuit is open or shorted.
  • Check if the engine overheats if the value indicated is higher than 135°C (275°F).
Powertrain > Engine > Data List

Tester Display

Coolant Temperature

OK:

The value of the display does not change frequently.

NG

GO TO COOLING SYSTEM

OK

2.

PERFORM ACTIVE TEST USING GTS

(a) Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test

Tester Display

Measurement Item

Control Range

Diagnostic Note

Front Left Air Mix Damper Control Servo Motor

No. 1 air conditioning radiator damper servo sub-assembly pulse

128: Min

384: Max

Operates between 165 to 257 pulses

Front Right Air Mix Damper Control Servo Motor

No. 1 air conditioning radiator damper servo sub-assembly pulse

128: Min

384: Max

Operates between 255 to 347 pulses

Body Electrical > Air Conditioner > Active Test

Active Test Display

Front Left Air Mix Damper Control Servo Motor

Data List Display

Front Left Air Mix Damper Control Servo Motor Actual Pulse

Body Electrical > Air Conditioner > Active Test

Active Test Display

Front Right Air Mix Damper Control Servo Motor

Data List Display

Front Right Air Mix Damper Control Servo Motor Actual Pulse

OK:

Damper servo motor is operated.

OK

REPLACE HEATER RADIATOR UNIT SUB-ASSEMBLY

NG

GO TO DTC TROUBLESHOOTING PROCEDURE FOR MALFUNCTIONING DAMPER SERVO MOTOR

    READ NEXT:

     Air Conditioning Unit

     Removal

    REMOVAL CAUTION / NOTICE / HINT COMPONENTS (REMOVAL) Procedure Part Name Code 1 PRECAUTION - - - 2 DRAIN ENGINE COOLANT -

     Disassembly

    DISASSEMBLY CAUTION / NOTICE / HINT COMPONENTS (DISASSEMBLY) Procedure Part Name Code 1 TRANSPONDER KEY ECU ASSEMBLY 89780 - - - 2 IMMO

    SEE MORE:

     Back Door Entry Lock and Unlock Functions do not Operate

    DESCRIPTION If the entry lock and unlock functions do not operate for the back door only, the request code may not be being transmitted from the back door. If the entry functions for other doors operate properly, communication between the electrical key transmitter sub-assembly and door control rece

     Telematics Transceiver Missing Message (B15DB87)

    DESCRIPTION When the radio and display receiver assembly cannot detect the telematics transceiver, this DTC will be stored. DTC No. Detection Item DTC Detection Condition Trouble Area DTC Output from Priority B15D

    © 2020-2024 Copyright www.tcorollacross.com