Toyota Corolla Cross Owners & Service Manuals

Toyota Corolla Cross: No Warm Air Comes Out

DESCRIPTION

If cool air blows from the registers regardless of the temperature setting of the air conditioning system, the following factors may be the cause.

Symptom

Factor

  • No warm air comes out

    (Blower control is normal)

  • Outlet air temperature does not increase

    (Blower control is normal)

  • Engine coolant temperature (low)
  • Air mix damper and link operation (jamming)
  • Warm-up control
  • Blockage in heater radiator unit sub-assembly
  • Heater radiator unit sub-assembly malfunction

PROCEDURE

1.

READ VALUE USING GTS (COOLANT TEMPERATURE)

(a) Read the Data List according to the display on the GTS.

Powertrain > Engine > Data List

Tester Display

Measurement Item

Range

Normal Condition

Diagnostic Note

Coolant Temperature

Engine coolant temperature

Min.: -40°C (-40°F)

Max.: 140°C (284°F)

75 to 100°C (167 to 212°F): After warming up

This is the engine coolant temperature.

HINT:

  • After warming up the engine, the engine coolant temperature will be 75 to 100°C (167 to 212°F).
  • After a long soak, the engine coolant temperature, intake air temperature and ambient air temperature will be approximately equal.
  • If the value is -40°C (-40°F), or higher than 135°C (275°F), the sensor circuit is open or shorted.
  • Check if the engine overheats if the value indicated is higher than 135°C (275°F).
Powertrain > Engine > Data List

Tester Display

Coolant Temperature

OK:

The value of the display does not change frequently.

NG

GO TO COOLING SYSTEM

OK

2.

PERFORM ACTIVE TEST USING GTS

(a) Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test

Tester Display

Measurement Item

Control Range

Diagnostic Note

Front Left Air Mix Damper Control Servo Motor

No. 1 air conditioning radiator damper servo sub-assembly pulse

128: Min

384: Max

Operates between 165 to 257 pulses

Front Right Air Mix Damper Control Servo Motor

No. 1 air conditioning radiator damper servo sub-assembly pulse

128: Min

384: Max

Operates between 255 to 347 pulses

Body Electrical > Air Conditioner > Active Test

Active Test Display

Front Left Air Mix Damper Control Servo Motor

Data List Display

Front Left Air Mix Damper Control Servo Motor Actual Pulse

Body Electrical > Air Conditioner > Active Test

Active Test Display

Front Right Air Mix Damper Control Servo Motor

Data List Display

Front Right Air Mix Damper Control Servo Motor Actual Pulse

OK:

Damper servo motor is operated.

OK

REPLACE HEATER RADIATOR UNIT SUB-ASSEMBLY

NG

GO TO DTC TROUBLESHOOTING PROCEDURE FOR MALFUNCTIONING DAMPER SERVO MOTOR

    READ NEXT:

     Air Conditioning System (for Gasoline Model With Manual Air Conditioning System)

     Precaution

    PRECAUTION DO NOT HANDLE REFRIGERANT IN AN ENCLOSED AREA OR NEAR AN OPEN FLAME *a Charging Cylinder ALWAYS WEAR EYE PROTECTION BE CAREFUL NOT TO GET LIQUID REFRIGERANT IN YOUR EYES O

     Parts Location

    PARTS LOCATION ILLUSTRATION *1 AIR CONDITIONER PRESSURE SENSOR *2 ECM *3 POWER STEERING ECU ASSEMBLY *4 NO. 1 ENGINE ROOM RELAY BLOCK ASSEMBLY - ECU-IGP NO. 3

    SEE MORE:

     Installation

    INSTALLATION CAUTION / NOTICE / HINT COMPONENTS (INSTALLATION) Procedure Part Name Code 1 TIRE PRESSURE WARNING VALVE AND TRANSMITTER 42607 - - 2

     Parts Location

    PARTS LOCATION ILLUSTRATION *1 NO. 1 ENGINE ROOM RELAY BLOCK ASSEMBLY - DEICER FUSE - ECU-IGP NO. 2 FUSE - DEICER RELAY *2 WINDSHIELD DEICER WIRE (WINDSHIELD GLASS) ILLUSTRATION *1 FRONT WIPER DEICER SWITCH *2 AIR CONDITIONING AMPLIFIER ASSEMBLY *3 AIR C

    © 2020-2024 Copyright www.tcorollacross.com