FREEZE FRAME DATA
FREEZE FRAME DATA
NOTICE:
(a) Check the freeze frame data on the GTS.
Chassis > EMPS
Tester Display |
Measurement Item |
Range |
Normal Condition |
Diagnostic Note |
---|---|---|---|---|
Total Distance Traveled |
Total distance traveled |
Min.: 0, Max.: 16777215 |
- |
- |
Total Distance Traveled - Unit |
Total Distance Traveled unit |
km / mile |
- |
- |
Vehicle Speed |
Vehicle speed from speedometer |
Min.: 0.0 km/h (0.0 MPH) Max.: 300.0 km/h (186.4 MPH) |
|
- |
Engine Revolution |
Engine speed |
Min.: 0 rpm Max.: 12800 rpm |
No significant fluctuation |
Engine running at a constant speed |
Ready Status |
Ready status |
OFF or ON |
- |
- |
Battery Voltage |
Auxiliary battery voltage |
Min.: 0.00 V Max.: 25.00 V |
11 to 14 V |
- |
Steering Wheel Torque |
Steering wheel torque |
Min.: -25.001 Nm Max.: 25.000 Nm |
Value changes in proportion to steering effort - The value increases when turning left and decreases when turning right |
Engine running and steering wheel being turned |
Steering Angle Velocity |
Steering angle speed |
Min.: -32768 deg/s Max.: 32767 deg/s |
Value changes in proportion to steering effort - The value increases when turning left and decreases when turning right |
Engine running and steering wheel being turned |
Steering Angle |
Steering angle |
Min.: -3072.0 deg Max.: 3070.5 deg |
- |
- |
Status of Vehicle Power (IGP PT2) |
State of IGP power source(PT2) |
OFF or ON |
OFF: Ignition switch off ON: Ignition switch ON |
- |
Status of Vehicle Power (IGP PT1) |
State of IGP power source(PT1) |
OFF or ON |
OFF: Ignition switch off ON: Ignition switch ON |
- |
Status of Vehicle Power (IGP PDC) |
State of IGP power source(PDC) |
OFF or ON |
OFF: Ignition switch off ON: Ignition switch ON |
- |
Status of Vehicle Power (IGR PDC) |
State of IGR power source(PDC) |
OFF or ON |
OFF: Ignition switch off ON: Ignition switch ON |
- |
IG Power Supply |
IG power source voltage |
Min.: 0.00 V Max.: 25.00 V |
8 to 16 V |
Ignition switch ON |
PIG Power Supply |
PIG power source voltage |
Min.: 0.00 V Max.: 25.00 V |
9 to 16 V |
Engine running and steering wheel being turned |
Thermistor Temperature |
ECU substrate temperature |
Min.: -50.0°C (-58.0°F) Max.: 200.0°C (392.0°F) |
-50°C to 200°C (-58°F to 392°F) |
- |
Power Source |
Operating state of hybrid system |
Operating State or Stopped State |
Operating State: Engine running Stopped State: Engine running |
- |
PS Assist Signal |
Status of the record of power steering assist signal |
Assist Stop or Under an Assist |
OFF: Assist stop ON: Under an assist |
- |
Synchronization Status of PWM |
Modulation synchronization state of the motor pulse wave duty ratio |
Synchronization State / Non-Synchronization State |
Synchronization State: Synchronized Non-Synchronization State: Not synchronized |
- |
Cooperation Control State |
Power steering operation control state |
Cooperation Control / Other than Cooperation Control |
Cooperation Control: Cooperation control Other than Cooperation Control: Other than cooperation control |
- |
Middle Voltage of Other Systems |
Middle voltage of other systems |
0.00 to 25.00 V |
- |
- |
Torque Sensor 1 Output |
Torque sensor 1 output value |
Min.: -25.000 Nm Max.: 25.001 Nm |
- |
- |
Torque Sensor 2 Output |
Torque sensor 2 output value |
Min.: -25.000 Nm Max.: 25.001 Nm |
- |
- |
Torque Sensor 3 Output |
Torque sensor 3 output value |
Min.: -25.000 Nm Max.: 25.001 Nm |
- |
- |
Torque Sensor 4 Output |
Torque sensor 4 output value |
Min.: -25.000 Nm Max.: 25.001 Nm |
- |
- |
Motor 1 U Phase Current |
Motor 1 terminal current (U phase) |
Min.: -327.68 A Max.: 327.67 A |
Value changes in proportion to steering effort |
Engine running and steering wheel being turned |
Motor 1 V Phase Current |
Motor 1 terminal current (V phase) |
Min.: -327.68 A Max.: 327.67 A |
Value changes in proportion to steering effort |
Engine running and steering wheel being turned |
Motor 1 W Phase Current |
Motor 1 terminal current (W phase) |
Min.: -327.68 A Max.: 327.67 A |
Value changes in proportion to steering effort |
Engine running and steering wheel being turned |
Motor 1 U Phase Duty |
Motor 1 U phase duty |
Min.: 0.00% Max.: 100.00% |
- |
- |
Motor 1 V Phase Duty |
Motor 1 V phase duty |
Min.: 0.00% Max.: 100.00% |
- |
- |
Motor 1 W Phase Duty |
Motor 1 W phase duty |
Min.: 0.00% Max.: 100.00% |
- |
- |
Motor 1 U Phase Terminal Voltage |
Motor 1 U phase terminal voltage |
0.00 to 100.00 V |
- |
- |
Motor 1 V Phase Terminal Voltage |
Motor 1 V phase terminal voltage |
0.00 to 100.00 V |
- |
- |
Motor 1 W Phase Terminal Voltage |
Motor 1 W phase terminal voltage |
0.00 to 100.00 V |
- |
- |
Motor 1 Power Supply |
Power supply voltage to active motor 1 |
Min.: 0.00 V Max.: 25.00 V |
9 to 16 V |
Engine running and steering wheel being turned |
Motor 2 U Phase Current |
Motor 2 terminal current (U phase) |
Min.: -327.68 A Max.: 327.67 A |
Value changes in proportion to steering effort |
Engine running and steering wheel being turned |
Motor 2 V Phase Current |
Motor 2 terminal current (V phase) |
Min.: -327.68 A Max.: 327.67 A |
Value changes in proportion to steering effort |
Engine running and steering wheel being turned |
Motor 2 W Phase Current |
Motor 2 terminal current (W phase) |
Min.: -327.68 A Max.: 327.67 A |
Value changes in proportion to steering effort |
Engine running and steering wheel being turned |
Motor 2 U Phase Duty |
Motor 2 U phase duty |
Min.: 0.00% Max.: 100.00% |
- |
- |
Motor 2 V Phase Duty |
Motor 2 V phase duty |
Min.: 0.00% Max.: 100.00% |
- |
- |
Motor 2 W Phase Duty |
Motor 2 W phase duty |
Min.: 0.00% Max.: 100.00% |
- |
- |
Motor 2 U Phase Terminal Voltage |
Motor 2 U phase terminal voltage |
0.00 to 100.00 V |
- |
- |
Motor 2 V Phase Terminal Voltage |
Motor 2 V phase terminal voltage |
0.00 to 100.00 V |
- |
- |
Motor 2 W Phase Terminal Voltage |
Motor 2 W phase terminal voltage |
0.00 to 100.00 V |
- |
- |
Motor 2 Power Supply |
Power supply voltage to active motor 2 |
Min.: 0.00 V Max.: 25.00 V |
9 to 16 V |
Engine running and steering wheel being turned |
Motor Rotation Angle 1 |
Motor rotation angle 1 |
0.0 to 360.1 deg / Unknown |
- |
- |
Motor Rotation Angle 2 |
Motor rotation angle 2 |
0.0 to 360.1 deg / Unknown |
- |
- |
Motor Rotation Angle 3 |
Motor rotation angle 3 |
0.0 to 360.1 deg / Unknown |
- |
- |
Motor Rotation Angle 4 |
Motor rotation angle 4 |
0.0 to 360.1 deg / Unknown |
- |
- |
Motor Rotation Angle Sensor 1 Sin Voltage |
Rotation angle sensor Sin1 output voltage used for rotation angle calculation |
Min.: 0.00 V Max.: 5.00 V |
- |
- |
Motor Rotation Angle Sensor 1 Cos Voltage |
Rotation angle sensor Cos1 output voltage used for rotation angle calculation |
Min.: 0.00 V Max.: 5.00 V |
- |
- |
Motor Rotation Angle Sensor 2 Sin Voltage |
Rotation angle sensor Sin2 output voltage used for rotation angle calculation |
Min.: 0.00 V Max.: 5.00 V |
- |
- |
Motor Rotation Angle Sensor 2 Cos Voltage |
Rotation angle sensor Cos2 output voltage used for rotation angle calculation |
Min.: 0.00 V Max.: 5.00 V |
- |
- |
Motor Rotation Angle Sensor 3 Sin Voltage |
Rotation angle sensor Sin3 output voltage used for rotation angle calculation |
Min.: 0.00 V Max.: 5.00 V |
- |
- |
Motor Rotation Angle Sensor 3 Cos Voltage |
Rotation angle sensor Cos3 output voltage used for rotation angle calculation |
Min.: 0.00 V Max.: 5.00 V |
- |
- |
Turn Counter 1 |
Turn counter 1 |
0 to 1024 |
- |
- |
Turn Counter 2 |
Turn counter 2 |
0 to 1024 |
- |
- |
Absolute Angle (Pinion Angle) |
Absolute angle (Pinion angle) |
-32.768 to 32.768 rad |
- |
- |
Steering Angle for the Steering Assembly |
Steering angle for the steering assembly |
-1877.5 to 1877.6 deg / Unknown |
- |
- |
Motor Actual Current (Q Axis) |
Detected current flow to motor (detected current of axis q) |
Min.: -327.68 A Max.: 327.67 A |
- |
- |
Command Value Current (Q Axis) |
Target current flow to motor (requested current of axis q) |
Min.: -327.68 A Max.: 327.67 A |
- |
- |
Motor Actual Current 2 (D Axis) |
Detected current flow to motor (detected current of axis d) |
Min.: -327.68 A Max.: 327.67 A |
- |
- |
Command Value Current 2 (D Axis) |
Target current flow to motor (requested current of axis d) |
Min.: -327.68 A Max.: 327.67 A |
- |
- |
Motor Rotation Angle |
Motor rotation angle (detected by rotation sensor) |
Min.: 0.0 deg Max.: 360.1 deg |
During steering operation, motor rotation angle value changes from 0 to 360° |
Engine running and steering wheel being turned |
Final Motor Current limited (Q Axis) |
Final motor current set limit (request current of axis q) |
Min.: 0.00 A Max.: 327.67 A |
- |
- |
Steering Angle Sensor Signal State |
State of steering angle sensor signal |
Usable, Unlearned, Sensor Fault, Communication Fault |
- |
- |
Eco-Run Control Mode |
Engine stop and start system control mode |
Eco Mode0 / Eco Mode1 / Eco Mode2 / Eco Mode3 / Eco Mode4 |
- |
- |
CAN Vehicle Speed (Speed Sensor RR) |
Speed sensor RR value sent via CAN |
Min.: 0 km/h (0 MPH) Max.: 255 km/h (158 MPH) |
|
- |
CAN Vehicle Speed (Speed Sensor RL) |
Speed sensor RL value sent via CAN |
Min.: 0 km/h (0 MPH) Max.: 255 km/h (158 MPH) |
|
- |
CAN Vehicle Speed (SP1) |
Vehicle speed input value sent via CAN (equal to value indicated on speedometer) |
Min.: 0.0 km/h (0.0 MPH) Max.: 300.0 km/h (186.4 MPH) |
|
- |
CAN Steering Angle Speed (SSAV) |
Steering wheel turning speed value sent via CAN |
Min.: -32768 deg/s Max.: 32767 deg/s |
- |
- |
Control State Information |
Control status information |
Min.: 0 Max.: 65535 |
- |
Although the item is displayed on the GTS, it is not applicable to the vehicle. |
ASIC State Information |
Integrated circuit state information |
Min.: 0 Max.: 65535 |
- |
Although the item is displayed on the GTS, it is not applicable to the vehicle. |
ECU Overheat Prevention Part |
Internal component of ECU for which overheat protection control is performed |
No Target Part, Inverter MOS, Power Supply Relay MOS, Custom IC, Choke Coil, H Bridge MOS, Motor Relay MOS, Around Microcomputer or DBC |
- |
- |
ECU Estimate Temperature of Overheat Prevention Part |
Estimated temperature of internal component of ECU for which overheat protection control is performed |
Min.: -50.0°C (-58.0°F) Max.: 200.1°C (392.2°F) |
- |
- |
Motor Overheat Prevention Part |
Internal component of motor for which overheat protection control is performed |
No Target Part, Motor |
- |
- |
Motor Estimate Temperature of Overheat Prevention Part |
Estimated temperature of internal component of motor for which overheat protection control is performed |
Min.: -50.0°C (-58.0°F) Max.: 200.1°C (392.2°F) |
- |
- |
Battery Voltage (System 2) |
Auxiliary battery voltage (System 2) |
0.00 to 25.00 V |
11 to 14 V: Ignition switch ON |
- |
IG Power Supply (System 2) |
ECU power supply status (System 2) |
0.00 to 25.00 V |
8 to 16 V: Ignition switch ON |
- |
PIG Power Supply (System 2) |
PIG power supply voltage (System 2) |
0.00 to 25.00 V |
9 to 16 V: Ignition switch ON and power steering operating |
- |
Thermistor Temperature (System 2) |
ECU substrate temperature (System 2) |
-50.0 to 200.0°C (-58 to 392°F) |
- |
- |
Middle Voltage of Other Systems (System 2) |
Middle voltage of other systems (System 2) |
0.00 to 25.00 V |
- |
- |
Motor Actual Current (Q Axis) (System 2) |
Motor command current (Q axis) (System 2 |
-327.68 to 327.67 A |
- |
- |
Command Value Current (Q Axis) (System 2) |
Motor command current (Q axis) (System 2) |
-327.68 to 327.67 A |
- |
- |
Motor Actual Current 2 (D Axis) (System 2) |
Motor current 2 (D axis) (System 2) |
-327.68 to 327.67 A |
- |
- |
Command Value Current 2 (D Axis) (System 2) |
Motor command current 2 (D axis) (System 2) |
-327.68 to 327.67 A |
- |
- |
Motor Rotation Angle (System 2) |
Motor rotation angle (System 2) |
0.0 to 360.0 deg / Unknown |
Value changes from 0 to 360°: Ignition switch ON and steering wheel being turned |
- |
Final Motor Current Limited (Q Axis) (System 2) |
Final motor current limit value (Q axis) (System 2) |
0.00 to 327.67 A |
- |
- |
ASIC State Information (System 2) |
Integrated circuit state information (System 2) |
0 to 65535 |
- |
- |