Toyota Corolla Cross Owners & Service Manuals

Toyota Corolla Cross: Freeze Frame Data

FREEZE FRAME DATA

FREEZE FRAME DATA

NOTICE:

  • It is difficult to show the specified values (judgment values) clearly because freeze frame data values change significantly due to differences in measurement conditions, surroundings, or vehicle conditions. For this reason, there may be a problem even when the values are within specification.
  • Turn the ignition switch to ON and park the vehicle on level ground. Check the freeze frame data by using the GTS.

(a) Check the freeze frame data on the GTS.

Chassis > EMPS

Tester Display

Measurement Item

Range

Normal Condition

Diagnostic Note

Total Distance Traveled

Total distance traveled

Min.: 0, Max.: 16777215

-

-

Total Distance Traveled - Unit

Total Distance Traveled unit

km / mile

-

-

Vehicle Speed

Vehicle speed from speedometer

Min.: 0.0 km/h (0.0 MPH)

Max.: 300.0 km/h (186.4 MPH)

  • 0 km/h (0 MPH): Engine running and vehicle stopped
  • No significant fluctuation: Engine running and vehicle driven at a constant speed

-

Engine Revolution

Engine speed

Min.: 0 rpm

Max.: 12800 rpm

No significant fluctuation

Engine running at a constant speed

Ready Status

Ready status

OFF or ON

-

-

Battery Voltage

Auxiliary battery voltage

Min.: 0.00 V

Max.: 25.00 V

11 to 14 V

-

Steering Wheel Torque

Steering wheel torque

Min.: -25.001 Nm

Max.: 25.000 Nm

Value changes in proportion to steering effort

- The value increases when turning left and decreases when turning right

Engine running and steering wheel being turned

Steering Angle Velocity

Steering angle speed

Min.: -32768 deg/s

Max.: 32767 deg/s

Value changes in proportion to steering effort

- The value increases when turning left and decreases when turning right

Engine running and steering wheel being turned

Steering Angle

Steering angle

Min.: -3072.0 deg

Max.: 3070.5 deg

-

-

Status of Vehicle Power (IGP PT2)

State of IGP power source(PT2)

OFF or ON

OFF: Ignition switch off

ON: Ignition switch ON

-

Status of Vehicle Power (IGP PT1)

State of IGP power source(PT1)

OFF or ON

OFF: Ignition switch off

ON: Ignition switch ON

-

Status of Vehicle Power (IGP PDC)

State of IGP power source(PDC)

OFF or ON

OFF: Ignition switch off

ON: Ignition switch ON

-

Status of Vehicle Power (IGR PDC)

State of IGR power source(PDC)

OFF or ON

OFF: Ignition switch off

ON: Ignition switch ON

-

IG Power Supply

IG power source voltage

Min.: 0.00 V

Max.: 25.00 V

8 to 16 V

Ignition switch ON

PIG Power Supply

PIG power source voltage

Min.: 0.00 V

Max.: 25.00 V

9 to 16 V

Engine running and steering wheel being turned

Thermistor Temperature

ECU substrate temperature

Min.: -50.0°C (-58.0°F)

Max.: 200.0°C (392.0°F)

-50°C to 200°C (-58°F to 392°F)

-

Power Source

Operating state of hybrid system

Operating State or Stopped State

Operating State: Engine running

Stopped State: Engine running

-

PS Assist Signal

Status of the record of power steering assist signal

Assist Stop or Under an Assist

OFF: Assist stop

ON: Under an assist

-

Synchronization Status of PWM

Modulation synchronization state of the motor pulse wave duty ratio

Synchronization State / Non-Synchronization State

Synchronization State: Synchronized

Non-Synchronization State: Not synchronized

-

Cooperation Control State

Power steering operation control state

Cooperation Control / Other than Cooperation Control

Cooperation Control: Cooperation control

Other than Cooperation Control: Other than cooperation control

-

Middle Voltage of Other Systems

Middle voltage of other systems

0.00 to 25.00 V

-

-

Torque Sensor 1 Output

Torque sensor 1 output value

Min.: -25.000 Nm

Max.: 25.001 Nm

-

-

Torque Sensor 2 Output

Torque sensor 2 output value

Min.: -25.000 Nm

Max.: 25.001 Nm

-

-

Torque Sensor 3 Output

Torque sensor 3 output value

Min.: -25.000 Nm

Max.: 25.001 Nm

-

-

Torque Sensor 4 Output

Torque sensor 4 output value

Min.: -25.000 Nm

Max.: 25.001 Nm

-

-

Motor 1 U Phase Current

Motor 1 terminal current (U phase)

Min.: -327.68 A

Max.: 327.67 A

Value changes in proportion to steering effort

Engine running and steering wheel being turned

Motor 1 V Phase Current

Motor 1 terminal current (V phase)

Min.: -327.68 A

Max.: 327.67 A

Value changes in proportion to steering effort

Engine running and steering wheel being turned

Motor 1 W Phase Current

Motor 1 terminal current (W phase)

Min.: -327.68 A

Max.: 327.67 A

Value changes in proportion to steering effort

Engine running and steering wheel being turned

Motor 1 U Phase Duty

Motor 1 U phase duty

Min.: 0.00%

Max.: 100.00%

-

-

Motor 1 V Phase Duty

Motor 1 V phase duty

Min.: 0.00%

Max.: 100.00%

-

-

Motor 1 W Phase Duty

Motor 1 W phase duty

Min.: 0.00%

Max.: 100.00%

-

-

Motor 1 U Phase Terminal Voltage

Motor 1 U phase terminal voltage

0.00 to 100.00 V

-

-

Motor 1 V Phase Terminal Voltage

Motor 1 V phase terminal voltage

0.00 to 100.00 V

-

-

Motor 1 W Phase Terminal Voltage

Motor 1 W phase terminal voltage

0.00 to 100.00 V

-

-

Motor 1 Power Supply

Power supply voltage to active motor 1

Min.: 0.00 V

Max.: 25.00 V

9 to 16 V

Engine running and steering wheel being turned

Motor 2 U Phase Current

Motor 2 terminal current (U phase)

Min.: -327.68 A

Max.: 327.67 A

Value changes in proportion to steering effort

Engine running and steering wheel being turned

Motor 2 V Phase Current

Motor 2 terminal current (V phase)

Min.: -327.68 A

Max.: 327.67 A

Value changes in proportion to steering effort

Engine running and steering wheel being turned

Motor 2 W Phase Current

Motor 2 terminal current (W phase)

Min.: -327.68 A

Max.: 327.67 A

Value changes in proportion to steering effort

Engine running and steering wheel being turned

Motor 2 U Phase Duty

Motor 2 U phase duty

Min.: 0.00%

Max.: 100.00%

-

-

Motor 2 V Phase Duty

Motor 2 V phase duty

Min.: 0.00%

Max.: 100.00%

-

-

Motor 2 W Phase Duty

Motor 2 W phase duty

Min.: 0.00%

Max.: 100.00%

-

-

Motor 2 U Phase Terminal Voltage

Motor 2 U phase terminal voltage

0.00 to 100.00 V

-

-

Motor 2 V Phase Terminal Voltage

Motor 2 V phase terminal voltage

0.00 to 100.00 V

-

-

Motor 2 W Phase Terminal Voltage

Motor 2 W phase terminal voltage

0.00 to 100.00 V

-

-

Motor 2 Power Supply

Power supply voltage to active motor 2

Min.: 0.00 V

Max.: 25.00 V

9 to 16 V

Engine running and steering wheel being turned

Motor Rotation Angle 1

Motor rotation angle 1

0.0 to 360.1 deg / Unknown

-

-

Motor Rotation Angle 2

Motor rotation angle 2

0.0 to 360.1 deg / Unknown

-

-

Motor Rotation Angle 3

Motor rotation angle 3

0.0 to 360.1 deg / Unknown

-

-

Motor Rotation Angle 4

Motor rotation angle 4

0.0 to 360.1 deg / Unknown

-

-

Motor Rotation Angle Sensor 1 Sin Voltage

Rotation angle sensor Sin1 output voltage used for rotation angle calculation

Min.: 0.00 V

Max.: 5.00 V

-

-

Motor Rotation Angle Sensor 1 Cos Voltage

Rotation angle sensor Cos1 output voltage used for rotation angle calculation

Min.: 0.00 V

Max.: 5.00 V

-

-

Motor Rotation Angle Sensor 2 Sin Voltage

Rotation angle sensor Sin2 output voltage used for rotation angle calculation

Min.: 0.00 V

Max.: 5.00 V

-

-

Motor Rotation Angle Sensor 2 Cos Voltage

Rotation angle sensor Cos2 output voltage used for rotation angle calculation

Min.: 0.00 V

Max.: 5.00 V

-

-

Motor Rotation Angle Sensor 3 Sin Voltage

Rotation angle sensor Sin3 output voltage used for rotation angle calculation

Min.: 0.00 V

Max.: 5.00 V

-

-

Motor Rotation Angle Sensor 3 Cos Voltage

Rotation angle sensor Cos3 output voltage used for rotation angle calculation

Min.: 0.00 V

Max.: 5.00 V

-

-

Turn Counter 1

Turn counter 1

0 to 1024

-

-

Turn Counter 2

Turn counter 2

0 to 1024

-

-

Absolute Angle (Pinion Angle)

Absolute angle (Pinion angle)

-32.768 to 32.768 rad

-

-

Steering Angle for the Steering Assembly

Steering angle for the steering assembly

-1877.5 to 1877.6 deg / Unknown

-

-

Motor Actual Current (Q Axis)

Detected current flow to motor (detected current of axis q)

Min.: -327.68 A

Max.: 327.67 A

-

-

Command Value Current (Q Axis)

Target current flow to motor (requested current of axis q)

Min.: -327.68 A

Max.: 327.67 A

-

-

Motor Actual Current 2 (D Axis)

Detected current flow to motor (detected current of axis d)

Min.: -327.68 A

Max.: 327.67 A

-

-

Command Value Current 2 (D Axis)

Target current flow to motor (requested current of axis d)

Min.: -327.68 A

Max.: 327.67 A

-

-

Motor Rotation Angle

Motor rotation angle (detected by rotation sensor)

Min.: 0.0 deg

Max.: 360.1 deg

During steering operation, motor rotation angle value changes from 0 to 360°

Engine running and steering wheel being turned

Final Motor Current limited (Q Axis)

Final motor current set limit (request current of axis q)

Min.: 0.00 A

Max.: 327.67 A

-

-

Steering Angle Sensor Signal State

State of steering angle sensor signal

Usable, Unlearned, Sensor Fault, Communication Fault

-

-

Eco-Run Control Mode

Engine stop and start system control mode

Eco Mode0 / Eco Mode1 / Eco Mode2 / Eco Mode3 / Eco Mode4

-

-

CAN Vehicle Speed (Speed Sensor RR)

Speed sensor RR value sent via CAN

Min.: 0 km/h (0 MPH)

Max.: 255 km/h (158 MPH)

  • 0 km/h (0 MPH): Engine running and vehicle stopped
  • No significant fluctuation: Engine running and vehicle driven at a constant speed

-

CAN Vehicle Speed (Speed Sensor RL)

Speed sensor RL value sent via CAN

Min.: 0 km/h (0 MPH)

Max.: 255 km/h (158 MPH)

  • 0 km/h (0 MPH): Engine running and vehicle stopped
  • No significant fluctuation: Engine running and vehicle driven at a constant speed

-

CAN Vehicle Speed (SP1)

Vehicle speed input value sent via CAN (equal to value indicated on speedometer)

Min.: 0.0 km/h (0.0 MPH)

Max.: 300.0 km/h (186.4 MPH)

  • 0 km/h (0 MPH): Engine running and vehicle stopped
  • No significant fluctuation: Engine running and vehicle driven at a constant speed

-

CAN Steering Angle Speed (SSAV)

Steering wheel turning speed value sent via CAN

Min.: -32768 deg/s

Max.: 32767 deg/s

-

-

Control State Information

Control status information

Min.: 0

Max.: 65535

-

Although the item is displayed on the GTS, it is not applicable to the vehicle.

ASIC State Information

Integrated circuit state information

Min.: 0

Max.: 65535

-

Although the item is displayed on the GTS, it is not applicable to the vehicle.

ECU Overheat Prevention Part

Internal component of ECU for which overheat protection control is performed

No Target Part, Inverter MOS, Power Supply Relay MOS, Custom IC, Choke Coil, H Bridge MOS, Motor Relay MOS, Around Microcomputer or DBC

-

-

ECU Estimate Temperature of Overheat Prevention Part

Estimated temperature of internal component of ECU for which overheat protection control is performed

Min.: -50.0°C (-58.0°F)

Max.: 200.1°C (392.2°F)

-

-

Motor Overheat Prevention Part

Internal component of motor for which overheat protection control is performed

No Target Part, Motor

-

-

Motor Estimate Temperature of Overheat Prevention Part

Estimated temperature of internal component of motor for which overheat protection control is performed

Min.: -50.0°C (-58.0°F)

Max.: 200.1°C (392.2°F)

-

-

Battery Voltage (System 2)

Auxiliary battery voltage (System 2)

0.00 to 25.00 V

11 to 14 V: Ignition switch ON

-

IG Power Supply (System 2)

ECU power supply status (System 2)

0.00 to 25.00 V

8 to 16 V: Ignition switch ON

-

PIG Power Supply (System 2)

PIG power supply voltage (System 2)

0.00 to 25.00 V

9 to 16 V: Ignition switch ON and power steering operating

-

Thermistor Temperature (System 2)

ECU substrate temperature (System 2)

-50.0 to 200.0°C (-58 to 392°F)

-

-

Middle Voltage of Other Systems (System 2)

Middle voltage of other systems (System 2)

0.00 to 25.00 V

-

-

Motor Actual Current (Q Axis) (System 2)

Motor command current (Q axis) (System 2

-327.68 to 327.67 A

-

-

Command Value Current (Q Axis) (System 2)

Motor command current (Q axis) (System 2)

-327.68 to 327.67 A

-

-

Motor Actual Current 2 (D Axis) (System 2)

Motor current 2 (D axis) (System 2)

-327.68 to 327.67 A

-

-

Command Value Current 2 (D Axis) (System 2)

Motor command current 2 (D axis) (System 2)

-327.68 to 327.67 A

-

-

Motor Rotation Angle (System 2)

Motor rotation angle (System 2)

0.0 to 360.0 deg / Unknown

Value changes from 0 to 360°: Ignition switch ON and steering wheel being turned

-

Final Motor Current Limited (Q Axis) (System 2)

Final motor current limit value (Q axis) (System 2)

0.00 to 327.67 A

-

-

ASIC State Information (System 2)

Integrated circuit state information (System 2)

0 to 65535

-

-

    READ NEXT:

     Fail-safe Chart

    FAIL-SAFE CHART If a problem occurs in the power steering system, the power steering assist will be stopped or the amount of power assist will be decreased to protect the system. Power Steering Sy

     Data List / Active Test

    DATA LIST / ACTIVE TEST DATA LIST HINT: Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This

     Diagnostic Trouble Code Chart

    DIAGNOSTIC TROUBLE CODE CHART Power Steering System DTC No. Detection Item Warning Indicate Link C05D604 Power Steering Contro

    SEE MORE:

     Installation

    INSTALLATION CAUTION / NOTICE / HINT COMPONENTS (INSTALLATION) Procedure Part Name Code 1 ENGINE STOP AND START ECU 89261A - - 2 POWER DISTRIBUTION BOX ASSEMBLY WITH MULTIPLEX NETWORK BODY ECU - - - - 3

     How To Proceed With Troubleshooting

    CAUTION / NOTICE / HINT HINT: Use the following procedure to troubleshoot the seat belt warning system. *: Use the GTS. PROCEDURE 1. VEHICLE BROUGHT TO WORKSHOP NEXT 2. CUSTOMER PROBLEM ANALYSIS (a) Interview the customer to conf

    © 2020-2024 Copyright www.tcorollacross.com