DIAGNOSTIC TROUBLE CODE CHART
Motor Generator Control System
DTC No. | Detection Item |
MIL | Warning Indicate |
Note | Link |
---|---|---|---|---|---|
P033506 | Crankshaft Position Sensor "A" Algorithm Based Failure |
Comes on | Master Warning: Comes on | SAE Code: P0336 |
|
P033516 | Crankshaft Position Sensor "A" Circuit Voltage Below Threshold |
Comes on | Master Warning: Comes on | SAE Code: P0337 |
|
P033517 | Crankshaft Position Sensor "A" Circuit Voltage Above Threshold |
Comes on | Master Warning: Comes on | SAE Code: P0338 |
|
P033523 | Crankshaft Position Sensor "A" Signal Stuck Low |
Comes on | Master Warning: Comes on | SAE Code: P0337 |
|
P033524 | Crankshaft Position Sensor "A" Signal Stuck High |
Comes on | Master Warning: Comes on | SAE Code: P0338 |
|
P033562 | Crankshaft Position Sensor "A" Signal Compare Failure |
Comes on | Master Warning: Comes on | SAE Code: P0336 |
|
P034006 | Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Algorithm Based Failure |
Comes on | Master Warning: Comes on | SAE Code: P0341 |
|
P034016 | Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Circuit Voltage Below Threshold |
Comes on | Master Warning: Comes on | SAE Code: P0342 |
|
P034017 | Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Circuit Voltage Above Threshold |
Comes on | Master Warning: Comes on | SAE Code: P0343 |
|
P034023 | Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Signal Stuck Low |
Comes on | Master Warning: Comes on | SAE Code: P0342 |
|
P034024 | Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Signal Stuck High |
Comes on | Master Warning: Comes on | SAE Code: P0343 |
|
P034062 | Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Signal Compare Failure |
Comes on | Master Warning: Comes on | SAE Code: P0341 |
|
P062F44 | Internal Control Module EEPROM Data Memory Failure |
Comes on | Master Warning: Does not come on | SAE Code: P062F |
|
P062F46 | Generator Control Module(EEPROM Learning Value) Calibration / Parameter Memory Failure |
Comes on | Master Warning: Comes on | SAE Code: P062F |
|
P06B01C | Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
Comes on | Master Warning: Comes on | SAE Code: P06B0 |
|
P06B31C | Drive Motor "B" Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
Comes on | Master Warning: Comes on | SAE Code: P06B3 |
|
P06B31F | Drive Motor "B" Control Module Position Sensor REF Power Source Circuit Intermittent |
Does not come on | Master Warning: Does not come on | SAE Code: P1C61 |
|
P06D61C | Generator Control Module Offset Power Circuit Voltage Out of Range |
Comes on | Master Warning: Comes on | SAE Code: P06D |
|
P0A0011 | Motor Electronics Coolant Temperature Sensor Circuit Short to Ground |
Comes on | Master Warning: Comes on | SAE Code: P0A02 |
|
P0A0015 | Motor Electronics Coolant Temperature Sensor Circuit Short to Battery or Open |
Comes on | Master Warning: Comes on | SAE Code: P0A03 |
|
P0A001C | Motor Electronics Coolant Temperature Sensor Circuit Voltage Out of Range |
Comes on | Master Warning: Comes on | SAE Code: P0A01 |
|
P0A1A47 | Generator Control Module Watchdog / Safety MC Failure |
Comes on | Master Warning: Comes on | SAE Code: P0A1A |
|
P0A1A49 | Generator Control Module Internal Electronic Failure |
Comes on | Master Warning: Comes on | SAE Code: P0A1A |
|
P0A1B1F | Generator Control Module Circuit Intermittent |
Comes on | Master Warning: Comes on | SAE Code: P0A1B |
|
P0A1B47 | Drive Motor "A" Control Module Watchdog / Safety MC Failure |
Comes on | Master Warning: Comes on | SAE Code: P0A1B |
|
P0A1B49 | Drive Motor "A" Control Module Internal Electronic Failure |
Comes on | Master Warning: Comes on | SAE Code: P0A1B |
|
P0A1B94 | Drive Motor "A" Control Module Unexpected Operation |
Comes on | Master Warning: Comes on | SAE Code: P0A1B |
|
P0A1C47 | Drive Motor "B" Control Module Watchdog / Safety MCU Failure |
Comes on | Master Warning: Comes on | SAE Code: P0A1C |
|
P0A1C49 | Drive Motor "B" Control Module Internal Electronic Failure |
Comes on | Master Warning: Comes on | SAE Code: P0A1C |
|
P0A2A11 | Drive Motor "A" Temperature Sensor Circuit Short to Ground |
Comes on | Master Warning: Comes on | SAE Code: P0A2C |
|
P0A2A15 | Drive Motor "A" Temperature Sensor Circuit Short to Auxiliary Battery or Open |
Comes on | Master Warning: Comes on | SAE Code: P0A2D |
|
P0A2A1C | Drive Motor "A" Temperature Sensor Voltage Out of Range |
Comes on | Master Warning: Comes on | SAE Code: P0A2B |
|
P0A2A1F | Drive Motor "A" Temperature Sensor Circuit Intermittent |
Comes on | Master Warning: Comes on | SAE Code: P0A2E |
|
P0A3611 | Generator Temperature Sensor Circuit Short to Ground |
Comes on | Master Warning: Comes on | SAE Code: P0A38 |
|
P0A3615 | Generator Temperature Sensor Circuit Short to Auxiliary Battery or Open |
Comes on | Master Warning: Comes on | SAE Code: P0A39 |
|
P0A361C | Generator Temperature Sensor Voltage Out of Range |
Comes on | Master Warning: Comes on | SAE Code: P0A37 |
|
P0A361F | Generator Temperature Sensor Circuit Intermittent |
Comes on | Master Warning: Comes on | SAE Code: P0A3A |
|
P0A3F16 | Drive Motor "A" Position Sensor Circuit Voltage Below Threshold |
Comes on | Master Warning: Comes on | SAE Code: P0A3F |
|
P0A3F1F | Drive Motor "A" Position Sensor Circuit Intermittent |
Does not come on | Master Warning: Does not come on | SAE Code: P0A43 |
|
P0A3F21 | Drive Motor "A" Position Sensor Signal Amplitude < Minimum |
Comes on | Master Warning: Comes on | SAE Code: P0A41 |
|
P0A3F22 | Drive Motor "A" Position Sensor Signal Amplitude > Maximum |
Comes on | Master Warning: Comes on | SAE Code: P0A42 |
|
P0A4516 | Drive Motor "B" Position Sensor Circuit Voltage Below Threshold |
Comes on | Master Warning: Comes on | SAE Code: P0A45 |
|
P0A451F | Drive Motor "B" Position Sensor Circuit Intermittent |
Does not come on | Master Warning: Does not come on | SAE Code: P0A49 |
|
P0A4521 | Drive Motor "B" Position Sensor Signal Amplitude < Minimum |
Comes on | Master Warning: Comes on | SAE Code: P0A47 |
|
P0A4522 | Drive Motor "B" Position Sensor Signal Amplitude > Maximum |
Comes on | Master Warning: Comes on | SAE Code: P0A48 |
|
P0A4B16 | Generator Position Sensor Circuit Voltage Below Threshold |
Comes on | Master Warning: Comes on | SAE Code: P0A4B |
|
P0A4B1F | Generator Position Sensor Circuit Intermittent |
Does not come on | Master Warning: Does not come on | SAE Code: P0A4F |
|
P0A4B21 | Generator Position Sensor Signal Amplitude < Minimum |
Comes on | Master Warning: Comes on | SAE Code: P0A4D |
|
P0A4B22 | Generator Position Sensor Signal Amplitude > Maximum |
Comes on | Master Warning: Comes on | SAE Code: P0A4E |
|
P0A6012 | Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Battery |
Does not come on | Master Warning: Comes on | SAE Code: P0A62 |
|
P0A6014 | Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Ground or Open |
Does not come on | Master Warning: Comes on | SAE Code: P0A61 |
|
P0A601C | Drive Motor "A" Phase V Current(High Resolution) Circuit Voltage Out of Range |
Does not come on | Master Warning: Comes on | SAE Code: P1C32 |
|
P0A601F | Drive Motor "A" Phase V Current(High Resolution) Circuit Intermittent |
Does not come on | Master Warning: Does not come on | SAE Code: P1C33 |
|
P0A6312 | Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Battery |
Does not come on | Master Warning: Comes on | SAE Code: P0A65 |
|
P0A6314 | Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Ground or Open |
Does not come on | Master Warning: Comes on | SAE Code: P0A64 |
|
P0A631C | Drive Motor "A" Phase W Current(High Resolution) Circuit Voltage Out of Range |
Does not come on | Master Warning: Comes on | SAE Code: P1C34 |
|
P0A631F | Drive Motor "A" Phase W Current(High Resolution) Circuit Intermittent |
Does not come on | Master Warning: Does not come on | SAE Code: P1C35 |
|
P0A6912 | Drive Motor "B" Phase V Current(High Resolution) Circuit Short to Battery |
Does not come on | Master Warning: Comes on | SAE Code: P0A6B |
|
P0A6914 | Drive Motor "B" Phase V Current(High Resolution) Circuit Short to Ground or Open |
Does not come on | Master Warning: Comes on | SAE Code: P0A6A |
|
P0A691C | Drive Motor "B" Phase V Current(High Resolution) Circuit Voltage Out of Range |
Does not come on | Master Warning: Comes on | SAE Code: P1C38 |
|
P0A691F | Drive Motor "B" Phase V Current(High Resolution) Circuit Intermittent |
Does not come on | Master Warning: Does not come on | SAE Code: P1C39 |
|
P0A6C12 | Drive Motor "B" Phase W Current(High Resolution) Circuit Short to Battery |
Does not come on | Master Warning: Comes on | SAE Code: P0A6E |
|
P0A6C14 | Drive Motor "B" Phase W Current(High Resolution) Circuit Short to Ground or Open |
Does not come on | Master Warning: Comes on | SAE Code: P0A6D |
|
P0A6C1C | Drive Motor "B" Phase W Current(High Resolution) Circuit Voltage Out of Range |
Does not come on | Master Warning: Comes on | SAE Code: P1C3A |
|
P0A6C1F | Drive Motor "B" Phase W Current(High Resolution) Circuit Intermittent |
Does not come on | Master Warning: Does not come on | SAE Code: P1C3B |
|
P0A7872 | Drive Motor "A" Inverter Actuator Stuck Open |
Comes on | Master Warning: Comes on | SAE Code: P0A78 |
|
P0A7873 | Drive Motor "A" Inverter Actuator Stuck Closed |
Comes on | Master Warning: Comes on | SAE Code: P0A78 |
|
P0A789E | Drive Motor "A" Inverter Stuck On |
Comes on | Master Warning: Comes on | SAE Code: P0A78 |
|
P0A7972 | Drive Motor "B" Inverter Actuator Stuck Open |
Comes on | Master Warning: Comes on | SAE Code: P0A79 |
|
P0A7973 | Drive Motor "B" Inverter Actuator Stuck Closed |
Comes on | Master Warning: Comes on | SAE Code: P0A79 |
|
P0A799E | Drive Motor "B" Inverter Stuck On |
Comes on | Master Warning: Comes on | SAE Code: P0A79 |
|
P0A7A72 | Generator Inverter Actuator Stuck Open |
Comes on | Master Warning: Comes on | SAE Code: P0A7A |
|
P0A7A73 | Generator Inverter Actuator Stuck Closed |
Comes on | Master Warning: Comes on | SAE Code: P0A7A |
|
P0A7A9E | Generator Inverter Stuck On |
Comes on | Master Warning: Comes on | SAE Code: P0A7A |
|
P0A9000 | Drive Motor "A" Performance |
Comes on | Master Warning: Comes on | SAE Code: P0A90 |
|
P0A9100 | Drive Motor "B" Performance |
Comes on | Master Warning: Comes on | SAE Code: P0A91 |
|
P0A9200 | Hybrid/EV Generator Performance |
Comes on | Master Warning: Comes on | SAE Code: P0A92 |
|
P0A949E | DC/DC Converter Stuck On |
Comes on | Master Warning: Comes on | SAE Code: P0A94 |
|
P0AED11 | Drive Motor Inverter Temperature Sensor "A" Circuit Short to Ground |
Comes on | Master Warning: Comes on | SAE Code: P0AEF |
|
P0AED15 | Drive Motor Inverter Temperature Sensor "A" Circuit Short to Battery or Open |
Comes on | Master Warning: Comes on | SAE Code: P0AF0 |
|
P0AED1C | Drive Motor Inverter Temperature Sensor "A" Circuit Voltage Out of Range |
Comes on | Master Warning: Comes on | SAE Code: P0AEE |
|
P0AF211 | Drive Motor Inverter Temperature Sensor "B" Circuit Short to Ground |
Comes on | Master Warning: Comes on | SAE Code: P0AF4 |
|
P0AF215 | Drive Motor Inverter Temperature Sensor "B" Circuit Short to Battery or Open |
Comes on | Master Warning: Comes on | SAE Code: P0AF5 |
|
P0AF21C | Drive Motor Inverter Temperature Sensor "B" Circuit Voltage Out of Range |
Comes on | Master Warning: Comes on | SAE Code: P0AF3 |
|
P0BCC11 | Generator Inverter Temperature Sensor Circuit Short to Ground |
Comes on | Master Warning: Comes on | SAE Code: P0BCE |
|
P0BCC15 | Generator Inverter Temperature Sensor Circuit Short to Battery or Open |
Comes on | Master Warning: Comes on | SAE Code: P0BCF |
|
P0BCC1C | Generator Inverter Temperature Sensor Circuit Voltage Out of Range |
Comes on | Master Warning: Comes on | SAE Code: P0BCD |
|
P0BE512 | Drive Motor "A" Phase U Current Sensor Circuit Short to Battery |
Comes on | Master Warning: Comes on | SAE Code: P0BE8 |
|
P0BE514 | Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open |
Comes on | Master Warning: Comes on | SAE Code: P0BE7 |
|
P0BE51F | Drive Motor "A" Phase U Current Sensor Circuit Intermittent |
Does not come on | Master Warning: Does not come on | SAE Code: P1C40 |
|
P0BE528 | Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on | Master Warning: Comes on | SAE Code: P0BE6 |
|
P0BE912 | Drive Motor "A" Phase V Current Sensor Circuit Short to Battery |
Comes on | Master Warning: Comes on | SAE Code: P0BEC |
|
P0BE914 | Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open |
Comes on | Master Warning: Comes on | SAE Code: P0BEB |
|
P0BE91F | Drive Motor "A" Phase V Current Sensor Circuit Intermittent |
Does not come on | Master Warning: Does not come on | SAE Code: P1C41 |
|
P0BE928 | Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on | Master Warning: Comes on | SAE Code: P0BEA |
|
P0BED12 | Drive Motor "A" Phase W Current Sensor Circuit Short to Battery |
Comes on | Master Warning: Comes on | SAE Code: P0BF0 |
|
P0BED14 | Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open |
Comes on | Master Warning: Comes on | SAE Code: P0BEF |
|
P0BED1F | Drive Motor "A" Phase W Current Sensor Circuit Intermittent |
Does not come on | Master Warning: Does not come on | SAE Code: P1C42 |
|
P0BED28 | Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on | Master Warning: Comes on | SAE Code: P0BEE |
|
P0BF112 | Drive Motor "B" Phase U Current Sensor Circuit Short to Battery |
Comes on | Master Warning: Comes on | SAE Code: P0BF4 |
|
P0BF114 | Drive Motor "B" Phase U Current Sensor Circuit Short to Ground or Open |
Comes on | Master Warning: Comes on | SAE Code: P0BF3 |
|
P0BF11F | Drive Motor "B" Phase U Current Sensor Circuit Intermittent |
Does not come on | Master Warning: Does not come on | SAE Code: P1C43 |
|
P0BF128 | Drive Motor "B" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on | Master Warning: Comes on | SAE Code: P0BF2 |
|
P0BF512 | Drive Motor "B" Phase V Current Sensor Circuit Short to Battery |
Comes on | Master Warning: Comes on | SAE Code: P0BF8 |
|
P0BF514 | Drive Motor "B" Phase V Current Sensor Circuit Short to Ground or Open |
Comes on | Master Warning: Comes on | SAE Code: P0BF7 |
|
P0BF51F | Drive Motor "B" Phase V Current Sensor Circuit Intermittent |
Does not come on | Master Warning: Does not come on | SAE Code: P1C44 |
|
P0BF528 | Drive Motor "B" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on | Master Warning: Comes on | SAE Code: P0BF6 |
|
P0BF912 | Drive Motor "B" Phase W Current Sensor Circuit Short to Battery |
Comes on | Master Warning: Comes on | SAE Code: P0BFC |
|
P0BF914 | Drive Motor "B" Phase W Current Sensor Circuit Short to Ground or Open |
Comes on | Master Warning: Comes on | SAE Code: P0BFB |
|
P0BF91F | Drive Motor "B" Phase W Current Sensor Circuit Intermittent |
Does not come on | Master Warning: Does not come on | SAE Code: P1C45 |
|
P0BF928 | Drive Motor "B" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on | Master Warning: Comes on | SAE Code: P0BFA |
|
P0BFD62 | Drive Motor "A" Phase U-V-W Current Sensor Signal Compare Failure |
Comes on | Master Warning: Comes on | SAE Code: P0BFD |
|
P0BFE62 | Drive Motor "B" Phase U-V-W Current Sensor Signal Compare Failure |
Comes on | Master Warning: Comes on | SAE Code: P0BFE |
|
P0BFF1D | Drive Motor "A" Circuit Current Out of Range |
Comes on | Master Warning: Comes on | SAE Code: P0BFF |
|
P0C021D | Drive Motor "B" System Circuit Current Out of Range |
Comes on | Master Warning: Comes on | SAE Code: P0C02 |
|
P0C1900 | Drive Motor "A" Execution Torque Performance |
Comes on | Master Warning: Comes on | SAE Code: P0C19 |
|
P0C1A00 | Drive Motor "B" Execution Torque Performance |
Comes on | Master Warning: Comes on | SAE Code: P0C1A |
|
P0C3811 | DC/DC Converter Temperature Sensor "A" Circuit Short to Ground |
Comes on | Master Warning: Comes on | SAE Code: P0C3A |
|
P0C3815 | DC/DC Converter Temperature Sensor "A" Circuit Short to Battery or Open |
Comes on | Master Warning: Comes on | SAE Code: P0C3B |
|
P0C381C | DC/DC Converter Temperature Sensor "A" Circuit Voltage Out of Range |
Comes on | Master Warning: Comes on | SAE Code: P0C39 |
|
P0C3D11 | DC/DC Converter Temperature Sensor "B" Circuit Short to Ground |
Comes on | Master Warning: Comes on | SAE Code: P0C3F |
|
P0C3D15 | DC/DC Converter Temperature Sensor "B" Circuit Short to Battery or Open |
Comes on | Master Warning: Comes on | SAE Code: P0C40 |
|
P0C3D1C | DC/DC Converter Temperature Sensor "B" Circuit Voltage Out of Range |
Comes on | Master Warning: Comes on | SAE Code: P0C3E |
|
P0C5013 | Drive Motor "A" Position Sensor Circuit "A" Circuit Open |
Comes on | Master Warning: Comes on | SAE Code: P0C50 |
|
P0C5016 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold |
Comes on | Master Warning: Comes on | SAE Code: P0C52 |
|
P0C5017 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold |
Comes on | Master Warning: Comes on | SAE Code: P0C53 |
|
P0C501F | Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent |
Does not come on | Master Warning: Does not come on | SAE Code: P0C54 |
|
P0C5513 | Drive Motor "B" Position Sensor Circuit "A" Circuit Open |
Comes on | Master Warning: Comes on | SAE Code: P0C55 |
|
P0C5516 | Drive Motor "B" Position Sensor Circuit "A" Circuit Voltage Below Threshold |
Comes on | Master Warning: Comes on | SAE Code: P0C57 |
|
P0C5517 | Drive Motor "B" Position Sensor Circuit "A" Circuit Voltage Above Threshold |
Comes on | Master Warning: Comes on | SAE Code: P0C58 |
|
P0C551F | Drive Motor "B" Position Sensor Circuit "A" Circuit Intermittent |
Does not come on | Master Warning: Does not come on | SAE Code: P0C59 |
|
P0C5A13 | Drive Motor "A" Position Sensor Circuit "B" Circuit Open |
Comes on | Master Warning: Comes on | SAE Code: P0C5A |
|
P0C5A16 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold |
Comes on | Master Warning: Comes on | SAE Code: P0C5C |
|
P0C5A17 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold |
Comes on | Master Warning: Comes on | SAE Code: P0C5D |
|
P0C5A1F | Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent |
Does not come on | Master Warning: Does not come on | SAE Code: P0C5E |
|
P0C5F13 | Drive Motor "B" Position Sensor Circuit "B" Circuit Open |
Comes on | Master Warning: Comes on | SAE Code: P0C5F |
|
P0C5F16 | Drive Motor "B" Position Sensor Circuit "B" Circuit Voltage Below Threshold |
Comes on | Master Warning: Comes on | SAE Code: P0C61 |
|
P0C5F17 | Drive Motor "B" Position Sensor Circuit "B" Circuit Voltage Above Threshold |
Comes on | Master Warning: Comes on | SAE Code: P0C62 |
|
P0C5F1F | Drive Motor "B" Position Sensor Circuit "B" Circuit Intermittent |
Does not come on | Master Warning: Does not come on | SAE Code: P0C63 |
|
P0C6413 | Generator Position Sensor Circuit "A" Circuit Open |
Comes on | Master Warning: Comes on | SAE Code: P0C64 |
|
P0C6416 | Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold |
Comes on | Master Warning: Comes on | SAE Code: P0C66 |
|
P0C6417 | Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold |
Comes on | Master Warning: Comes on | SAE Code: P0C67 |
|
P0C641F | Generator Position Sensor Circuit "A" Circuit Intermittent |
Does not come on | Master Warning: Does not come on | SAE Code: P0C68 |
|
P0C6913 | Generator Position Sensor Circuit "B" Circuit Open |
Comes on | Master Warning: Comes on | SAE Code: P0C69 |
|
P0C6916 | Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold |
Comes on | Master Warning: Comes on | SAE Code: P0C6B |
|
P0C6917 | Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold |
Comes on | Master Warning: Comes on | SAE Code: P0C6C |
|
P0C691F | Generator Position Sensor Circuit "B" Circuit Intermittent |
Does not come on | Master Warning: Does not come on | SAE Code: P0C6D |
|
P0C7917 | Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Above Threshold |
Comes on | Master Warning: Comes on | SAE Code: P0C79 |
|
P0CA300 | DC/DC Converter Step Up Voltage Performance |
Comes on | Master Warning: Comes on | SAE Code: P0CA3 |
|
P0D2D16 | Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Below Threshold |
Comes on | Master Warning: Comes on | SAE Code: P0D2F |
|
P0D2D17 | Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Above Threshold |
Comes on | Master Warning: Comes on | SAE Code: P0D30 |
|
P0D2D1F | Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Intermittent |
Does not come on | Master Warning: Does not come on | SAE Code: P0D31 |
|
P0D3319 | DC/DC Converter Circuit Current Above Threshold |
Comes on | Master Warning: Comes on | SAE Code: P0D33 |
|
P0DFA62 | Generator Phase U-V-W Current Sensor Signal Compare Failure |
Comes on | Master Warning: Comes on | SAE Code: P0DFA |
|
P0E0012 | Generator Phase U Current Sensor Circuit Short to Battery |
Comes on | Master Warning: Comes on | SAE Code: P0E03 |
|
P0E0014 | Generator Phase U Current Sensor Circuit Short to Ground or Open |
Comes on | Master Warning: Comes on | SAE Code: P0E02 |
|
P0E001F | Generator Phase U Current Sensor Circuit Intermittent |
Does not come on | Master Warning: Does not come on | SAE Code: P1C46 |
|
P0E0028 | Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on | Master Warning: Comes on | SAE Code: P0E01 |
|
P0E0412 | Generator Phase V Current Sensor Circuit Short to Battery |
Comes on | Master Warning: Comes on | SAE Code: P0E07 |
|
P0E0414 | Generator Phase V Current Sensor Circuit Short to Ground or Open |
Comes on | Master Warning: Comes on | SAE Code: P0E06 |
|
P0E041F | Generator Phase V Current Sensor Circuit Intermittent |
Does not come on | Master Warning: Does not come on | SAE Code: P1C47 |
|
P0E0428 | Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on | Master Warning: Comes on | SAE Code: P0E05 |
|
P0E0812 | Generator Phase W Current Sensor Circuit Short to Battery |
Comes on | Master Warning: Comes on | SAE Code: P0E0B |
|
P0E0814 | Generator Phase W Current Sensor Circuit Short to Ground or Open |
Comes on | Master Warning: Comes on | SAE Code: P0E0A |
|
P0E081F | Generator Phase W Current Sensor Circuit Intermittent |
Does not come on | Master Warning: Does not come on | SAE Code: P1C48 |
|
P0E0828 | Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on | Master Warning: Comes on | SAE Code: P0E09 |
|
P0E3116 | DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Below Threshold |
Comes on | Master Warning: Comes on | SAE Code: P0E33 |
|
P0E3117 | DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Above Threshold |
Comes on | Master Warning: Comes on | SAE Code: P0E34 |
|
P0E311F | DC/DC Converter Voltage Sensor "A"(VL) Circuit Intermittent |
Does not come on | Master Warning: Does not come on | SAE Code: P0E35 |
|
P0E5111 | DC/DC Converter Current Sensor Circuit Short to Ground |
Comes on | Master Warning: Comes on | SAE Code: P0E53 |
|
P0E5115 | DC/DC Converter Current Sensor Circuit Short to Battery or Open |
Comes on | Master Warning: Comes on | SAE Code: P0E54 |
|
P0E511F | DC/DC Converter Current Sensor Circuit Intermittent |
Does not come on | Master Warning: Does not come on | SAE Code: P0E55 |
|
P0E5128 | DC/DC Converter Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on | Master Warning: Comes on | SAE Code: P0E52 |
|
P0E512A | DC/DC Converter Current Sensor Signal Stuck In Range |
Comes on | Master Warning: Comes on | SAE Code: P0E52 |
|
P0E5717 | DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Above Threshold |
Comes on | Master Warning: Comes on | SAE Code: P0E57 |
|
P0E7100 | Generator Execution Torque Performance |
Comes on | Master Warning: Comes on | SAE Code: P0E71 |
|
P19F81C | Generator Control Module Offset Power Circuit Voltage Out of Range |
Comes on | Master Warning: Comes on | SAE Code: P19F8 |
|
P19F91C | Drive Motor "B" Control Module Offset Power Circuit Voltage Out of Range |
Comes on | Master Warning: Comes on | SAE Code: P19F9 |
|
P1C2A1C | Generator A/D Converter Circuit Circuit Voltage Out of Range |
Comes on | Master Warning: Comes on | SAE Code: P1C2A |
|
P1C2A49 | Generator A/D Converter Circuit Internal Electronic Failure |
Comes on | Master Warning: Comes on | SAE Code: P1C2A |
|
P1C2A71 | Generator A/D Converter Circuit Actuator Stuck |
Comes on | Master Warning: Comes on | SAE Code: P1C2A |
|
P1C2B1C | Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range |
Comes on | Master Warning: Comes on | SAE Code: P1C2B |
|
P1C2B49 | Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure |
Comes on | Master Warning: Comes on | SAE Code: P1C2B |
|
P1C2B71 | Drive Motor "A" Control Module A/D Converter Circuit Actuator Stuck |
Comes on | Master Warning: Comes on | SAE Code: P1C2B |
|
P1C2C1C | Drive Motor "B" Control Module AD Converter Circuit Voltage Out of Range |
Comes on | Master Warning: Comes on | SAE Code: P1C2C |
|
P1C2C49 | Drive Motor "B" Control Module AD Converter Internal Electronic Failure |
Comes on | Master Warning: Comes on | SAE Code: P1C2C |
|
P1C2C71 | Drive Motor "B" Control Module A/D Converter Circuit Actuator Stuck |
Comes on | Master Warning: Comes on | SAE Code: P1C2C |
|
P1C5D19 | Drive Motor "A" Inverter Circuit Current Above Threshold |
Comes on | Master Warning: Comes on | SAE Code: P1C5D |
|
P1C5E19 | Drive Motor "B" Inverter Circuit Current Above Threshold |
Comes on | Master Warning: Comes on | SAE Code: P1C5E |
|
P1C5F19 | Generator Inverter Circuit Current Above Threshold |
Comes on | Master Warning: Comes on | SAE Code: P1C5F |
|
P1C601F | Generator Control Module Position Sensor REF Power Source Circuit Intermittent |
Does not come on | Master Warning: Does not come on | SAE Code: P1C60 |
|
P1C621F | Generator Control Module Offset Power Circuit Intermittent |
Does not come on | Master Warning: Does not come on | SAE Code: P1C62 |
|
P1C641F | Generator Control Module Circuit Intermittent |
Does not come on | Master Warning: Does not come on | SAE Code: P1C64 |
|
P1C651F | Generator Control Module Circuit Intermittent |
Does not come on | Master Warning: Does not come on | SAE Code: P1C65 |
|
P1C661F | Drive Motor "B" Control Module Circuit Intermittent |
Does not come on | Master Warning: Does not come on | SAE Code: P1C66 |
|
P1C671F | Drive Motor "A" Phase U-V-W Current Sensor Circuit Intermittent |
Does not come on | Master Warning: Does not come on | SAE Code: P1C67 |
|
P1C681F | Drive Motor "B" Phase U-V-W Current Sensor Circuit Intermittent |
Does not come on | Master Warning: Does not come on | SAE Code: P1C68 |
|
P1C691F | Generator Phase U-V-W Current Sensor Circuit Intermittent |
Does not come on | Master Warning: Does not come on | SAE Code: P1C69 |
|
P1CA51D | Hybrid/EV Generator Circuit Current Out of Range |
Comes on | Master Warning: Comes on | SAE Code: P1CA5 |
|
P1CAC49 | Generator Position Sensor Internal Electronic Failure |
Comes on | Master Warning: Comes on | SAE Code: P1CAC |
|
P1CAD49 | Drive Motor "A" Position Sensor Internal Electronic Failure |
Comes on | Master Warning: Comes on | SAE Code: P1CAD |
|
P1CAE49 | Drive Motor "B" Position Sensor Internal Electronic Failure |
Comes on | Master Warning: Comes on | SAE Code: P1CAE |
|
P1CAF38 | Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect |
Comes on | Master Warning: Comes on | SAE Code: P1CAF |
|
P1CB038 | Drive Motor "A" Position Sensor REF Signal Frequency Incorrect |
Comes on | Master Warning: Comes on | SAE Code: P1CB0 |
|
P1CB138 | Drive Motor "B" Position Sensor REF Signal Frequency Incorrect |
Comes on | Master Warning: Comes on | SAE Code: P1CB1 |
|
P1CB59E | DC/DC Converter Voltage Sensor "A"(VL) Stuck On |
Comes on | Master Warning: Comes on | SAE Code: P0A94 |
|
P1CB69E | Drive Motor "A" Inverter Voltage Sensor(VH) Stuck On |
Comes on | Master Warning: Comes on | SAE Code: P0A78 |
|
P1CFF62 | Hybrid/EV Battery Current/DC/DC Converter Current Signal Compare Failure |
Comes on | Master Warning: Comes on | SAE Code: P1CFF |
|
P26DF1C | Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
Does not come on | Master Warning: Does not come on | SAE Code: P26DF |
|
P26DF1F | Generator Control Module Position Sensor REF Power Source Circuit Intermittent |
Does not come on | Master Warning: Does not come on | SAE Code: P19F7 |
|
P274A11 | Transmission Fluid Temperature Sensor "C" Circuit Short to Ground |
Comes on | Master Warning: Comes on | SAE Code: P274C |
|
P274A15 | Transmission Fluid Temperature Sensor "C" Circuit Short to Auxiliary Battery or Open |
Comes on | Master Warning: Comes on | SAE Code: P274D |
|
P274A1C | Transmission Fluid Temperature Sensor "C" Voltage Out of Range |
Comes on | Master Warning: Comes on | SAE Code: P274B |
|
P274A1F | Transmission Fluid Temperature Sensor "C" Circuit Intermittent |
Comes on | Master Warning: Comes on | SAE Code: P274E |
|
P310A1F | Communication Error from Drive Motor "B" to Drive Motor "A" Circuit Intermittent |
Does not come on | Master Warning: Does not come on | SAE Code: P310A |
|
P310A83 | Communication Error from Drive Motor "B" to Drive Motor "A" Value of Signal Protection Calculation Incorrect |
Comes on | Master Warning: Comes on | SAE Code: P310A |
|
P310A86 | Communication Error from Drive Motor "B" to Drive Motor "A" Signal (Some Circuit Quantity, Reported via Serial Data) Invalid |
Comes on | Master Warning: Comes on | SAE Code: P310A |
|
P310A87 | Communication Error from Drive Motor "B" to Drive Motor "A" Missing Message |
Comes on | Master Warning: Comes on | SAE Code: P310A |
|
P310B1F | Communication Error from Drive Motor "A" to Drive Motor "B" Circuit Intermittent |
Does not come on | Master Warning: Does not come on | SAE Code: P310B |
|
P310B83 | Communication Error from Drive Motor "A" to Drive Motor "B" Value of Signal Protection Calculation Incorrect |
Comes on | Master Warning: Comes on | SAE Code: P310B |
|
P310B86 | Communication Error from Drive Motor "A" to Drive Motor "B" Signal (Some Circuit Quantity, Reported via Serial Data) Invalid |
Comes on | Master Warning: Comes on | SAE Code: P310B |
|
P310B87 | Communication Error from Drive Motor "A" to Drive Motor "B" Missing Message |
Comes on | Master Warning: Comes on | SAE Code: P310B |
|
P31241F | Lost Communication between Drive Motor "A" and HV/EV ECU Circuit Intermittent |
Does not come on | Master Warning: Does not come on | SAE Code: P3124 |
|
P313383 | Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect |
Comes on | Master Warning: Comes on | SAE Code: P3133 |
|
P313386 | Communication Error from Generator to Drive Motor "A" Signal Invalid |
Comes on | Master Warning: Comes on | SAE Code: P3133 |
|
P313387 | Communication Error from Generator to Drive Motor "A" Missing Message |
Comes on | Master Warning: Comes on | SAE Code: P3133 |
|
P313483 | Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect |
Comes on | Master Warning: Comes on | SAE Code: P3134 |
|
P313486 | Communication Error from Drive Motor "A" to Generator Signal Invalid |
Comes on | Master Warning: Comes on | SAE Code: P3134 |
|
P313487 | Communication Error from Drive Motor "A" to Generator Missing Message |
Comes on | Master Warning: Comes on | SAE Code: P3134 |
|
P314F1F | DC/DC Converter Voltage Sensor "A"(VL) Circuit Intermittent |
Comes on | Master Warning: Comes on | SAE Code: P314F |
|
P31531D | DC/DC Converter Current Sensor Circuit Current Out of Range |
Does not come on | Master Warning: Comes on | SAE Code: P3153 |
|
P32BF1F | Lost Communication between Drive Motor "A" and "B" (Drive Motor "A") Circuit Intermittent |
Does not come on | Master Warning: Does not come on | SAE Code: P32BF |
|
P32BF83 | Lost Communication between Drive Motor "A" and "B" (Drive Motor "A") Value of Signal Protection Calculation Incorrect |
Comes on | Master Warning: Comes on | SAE Code: P32BF |
|
P32BF86 | Lost Communication between Drive Motor "A" and "B" (Drive Motor "A") Signal (Some Circuit Quantity, Reported via Serial Data) Invalid |
Comes on | Master Warning: Comes on | SAE Code: P32BF |
|
P32BF87 | Lost Communication between Drive Motor "A" and "B" (Drive Motor "A") Missing Message |
Comes on | Master Warning: Comes on | SAE Code: P32BF |
|
P32CF1F | Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Circuit Intermittent |
Does not come on | Master Warning: Does not come on | SAE Code: P32CF |
|
P32CF83 | Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Value of Signal Protection Calculation Incorrect |
Comes on | Master Warning: Comes on | SAE Code: P32CF |
|
P32CF86 | Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Signal (Some Circuit Quantity, Reported via Serial Data) Invalid |
Comes on | Master Warning: Comes on | SAE Code: P32CF |
|
P32CF87 | Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Missing Message |
Comes on | Master Warning: Comes on | SAE Code: P32CF |
|
U010087 | Lost Communication With ECM/PCM "A" Missing Message |
Comes on | Master Warning: Comes on | SAE Code: U0100 |
|
U029387 | Lost Communication With Hybrid Powertrain Control Module Missing Message |
Comes on | Master Warning: Comes on | SAE Code: U0293 |
|
U117008 | Lost Communication with Brake System Control Module (ch2) Bus Signal / Message Failure |
Does not come on | Master Warning: Comes on | SAE Code: U1170 |
|
U117087 | Lost Communication With Brake System Control Module(ch2) Missing Message |
Comes on | Master Warning: Comes on | SAE Code: U1170 |
|
U11B300 | Lost Communication with Hybrid/EV Powertrain Control Module (ch5) (System 2) Missing Message |
Comes on | Master Warning: Comes on | SAE Code: U11B3 |
|
U11B387 | Lost Communication with Hybrid/EV Powertrain Control Module (ch5) Missing Message |
Comes on | Master Warning: Comes on | SAE Code: U11B3 |
|