Toyota Corolla Cross: Weak Blower Output

DESCRIPTION

If the airflow from the front registers is weak regardless of the blower speed setting displayed on the air conditioning control assembly, the following factors may be the cause.

Symptom

Factor

  • Airflow volume is constantly low
  • Airflow volume sometimes becomes low
  • Blower motor with fan sub-assembly malfunction
  • ECO mode control of air conditioning system is enabled
  • Clogged clean air filter
  • Clogged No. 1 cooler evaporator sub-assembly or heater radiator unit sub-assembly fins
  • No. 1 cooler thermistor malfunction
  • Aspirator not connected properly

PROCEDURE

1.

CHECK AIR CONDITIONING SYSTEM

(a) Operate the blower switch with the following conditions met and check that the airflow volume changes.

Blower Speed

Condition

LO → HI

  • Temperature setting: MAX COLD
  • Air outlet mode: FACE
  • A/C switch: Off

OK:

Airflow volume increases.

NG

GO TO OTHER DIAGNOSIS PROCEDURE (Blower Motor Circuit)

OK

2.

CHECK CLEAN AIR FILTER

(a) Visually check the clean air filter.

Click here

OK:

The clean air filter is not dirty or clogged.

NG

REPLACE CLEAN AIR FILTER

OK

3.

CHECK NO. 1 COOLER THERMISTOR

(a) Check the installation condition of the No. 1 cooler thermistor.

OK:

The No. 1 cooler thermistor is installed correctly.

NG

INSTALL NO. 1 COOLER THERMISTOR

OK

4.

CHECK ASPIRATOR

(a) Check the installation condition of the aspirator.

OK:

The aspirator is installed correctly.

OK

REPLACE HEATER RADIATOR UNIT SUB-ASSEMBLY OR NO. 1 COOLER EVAPORATOR SUB-ASSEMBLY

NG

INSTALL ASPIRATOR

    READ NEXT:

     Recirculated/Fresh Air Modes Switch without User Input

    DESCRIPTION If recirculation/fresh mode changes unintentionally and without permission, the following causes are possible. Symptom Factor Recirculation/fresh mode changes without

     Recirculated/Fresh Air Modes do not Switch

    DESCRIPTION If the air inlet mode cannot be changed between recirculation/fresh or exhaust gas odors can be smelled even though recirculation mode is selected, the following factors may be the cause.

     No Cool Air Comes Out

    DESCRIPTION If warm air blows from the registers regardless of the temperature setting of the air conditioning system, the following factors may be the cause. Symptom Factor No cool ai

    SEE MORE:

     Revolution Sensor (nss Sensor)

    Removal REMOVAL CAUTION / NOTICE / HINT COMPONENTS (REMOVAL) Procedure Part Name Code 1 TCM 89535B - - - 2 TRANSMISSION REVOLUTION SENSOR (NSS)

     Inspection

    INSPECTION PROCEDURE 1. INSPECT FRONT DRIVE SHAFT ASSEMBLY (a) Check that there is no excessive play in the radial direction of the outboard joint. (b) Check that the inboard joint slides smoothly in the thrust direction. (c) Check t

    © 2020-2024 Copyright www.tcorollacross.com