Toyota Corolla Cross: Weak Blower Output

DESCRIPTION

If the airflow from the front registers is weak regardless of the blower speed setting displayed on the air conditioning control assembly, the following factors may be the cause.

Symptom

Factor

  • Airflow volume is constantly low
  • Airflow volume sometimes becomes low
  • Blower motor with fan sub-assembly malfunction
  • ECO mode control of air conditioning system is enabled
  • Clogged clean air filter
  • Clogged No. 1 cooler evaporator sub-assembly or heater radiator unit sub-assembly fins
  • No. 1 cooler thermistor malfunction
  • Aspirator not connected properly

PROCEDURE

1.

CHECK AIR CONDITIONING SYSTEM

(a) Operate the blower switch with the following conditions met and check that the airflow volume changes.

Blower Speed

Condition

LO → HI

  • Temperature setting: MAX COLD
  • Air outlet mode: FACE
  • A/C switch: Off

OK:

Airflow volume increases.

NG

GO TO OTHER DIAGNOSIS PROCEDURE (Blower Motor Circuit)

OK

2.

CHECK CLEAN AIR FILTER

(a) Visually check the clean air filter.

Click here

OK:

The clean air filter is not dirty or clogged.

NG

REPLACE CLEAN AIR FILTER

OK

3.

CHECK NO. 1 COOLER THERMISTOR

(a) Check the installation condition of the No. 1 cooler thermistor.

OK:

The No. 1 cooler thermistor is installed correctly.

NG

INSTALL NO. 1 COOLER THERMISTOR

OK

4.

CHECK ASPIRATOR

(a) Check the installation condition of the aspirator.

OK:

The aspirator is installed correctly.

OK

REPLACE HEATER RADIATOR UNIT SUB-ASSEMBLY OR NO. 1 COOLER EVAPORATOR SUB-ASSEMBLY

NG

INSTALL ASPIRATOR

    READ NEXT:

     Recirculated/Fresh Air Modes Switch without User Input

    DESCRIPTION If recirculation/fresh mode changes unintentionally and without permission, the following causes are possible. Symptom Factor Recirculation/fresh mode changes without

     Recirculated/Fresh Air Modes do not Switch

    DESCRIPTION If the air inlet mode cannot be changed between recirculation/fresh or exhaust gas odors can be smelled even though recirculation mode is selected, the following factors may be the cause.

     No Cool Air Comes Out

    DESCRIPTION If warm air blows from the registers regardless of the temperature setting of the air conditioning system, the following factors may be the cause. Symptom Factor No cool ai

    SEE MORE:

     All Door Entry Lock/Unlock Functions and Wireless Functions do not Operate

    DESCRIPTION If the entry lock and wireless door lock operations cannot be performed, the door control receiver may be malfunctioning, or there may be wave interference or problems in the communication which is used for the entry and wireless function between the door control receiver and certificati

     Removal

    REMOVAL CAUTION / NOTICE / HINT COMPONENTS (REMOVAL) Procedure Part Name Code 1 FRONT BUMPER ASSEMBLY - - - - 2 WASHER INLET SUB-ASSEMBLY 85301 - - - 3 HEADLIGHT ASSEMBLY - - - *A for RH Side

    © 2020-2024 Copyright www.tcorollacross.com