DESCRIPTION
If warm air blows from the registers regardless of the temperature setting of the air conditioning system, the following factors may be the cause.
Symptom | Factor |
---|---|
No cool air comes out
|
|
PROCEDURE
1. |
CHECK SWITCH INDICATOR |
(a) Operate each switch on the air conditioning control assembly and check that the switch indicators operate normally.
OK:
All switch indicators operate normally.
NG | GO TO OTHER DIAGNOSIS PROCEDURE (Operation not Accepted Even If Air Conditioning Switch is Operated) |
|
2. |
PERFORM ACTIVE TEST USING GTS |
(a) Perform the Active Test according to the display on the GTS.
Body Electrical > Air Conditioner > Active Test
Tester Display | Measurement Item |
Control Range | Diagnostic Note |
---|---|---|---|
Front Air Mix Damper Control Servo Motor |
No. 1 air conditioning radiator damper servo sub-assembly pulse |
Min.: 128 Max.: 384 |
- |
Active Test Display |
---|
Front Air Mix Damper Control Servo Motor |
Data List Display |
---|
Front Air Mix Damper Control Servo Motor Actual Pulse |
OK:
The No. 1 air conditioning radiator damper servo motor operates.
OK | INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET |
NG | GO TO DTC TROUBLESHOOTING PROCEDURE FOR MALFUNCTIONING DAMPER SERVO MOTOR |