Toyota Corolla Cross Owners & Service Manuals

Toyota Corolla Cross: Vehicle Behavior Chart

VEHICLE BEHAVIOR CHART

VEHICLE BEHAVIOR CHART

(a) Vehicle behavior categorized by DTC

If a DTC is output, the vehicle behaves as follows.

DTC No.

Detection Item

Vehicle Behavior when DTC is Output

P033506

Crankshaft Position Sensor "A" Algorithm Based Failure

Normal driving

P033516

Crankshaft Position Sensor "A" Circuit Voltage Below Threshold

Normal driving

P033517

Crankshaft Position Sensor "A" Circuit Voltage Above Threshold

Normal driving

P033523

Crankshaft Position Sensor "A" Signal Stuck Low

Normal driving

P033524

Crankshaft Position Sensor "A" Signal Stuck High

Normal driving

P033562

Crankshaft Position Sensor "A" Signal Compare Failure

Normal driving

P034006

Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Algorithm Based Failure

Normal driving

P034016

Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Circuit Voltage Below Threshold

Normal driving

P034017

Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Circuit Voltage Above Threshold

Normal driving

P034023

Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Signal Stuck Low

Normal driving

P034024

Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Signal Stuck High

Normal driving

P034062

Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Signal Compare Failure

Normal driving

P062F44

Internal Control Module EEPROM Data Memory Failure

Normal driving

P062F46

Generator Control Module (EEPROM Learning Value) Calibration / Parameter Memory Failure

Reduced output power

P06B01C

Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range

Hybrid system stopped

P06B31C

Drive Motor "B" Control Module Position Sensor REF Power Source Circuit Voltage Out of Range

AWD stopped

P06B31F

Drive Motor "B" Control Module Position Sensor REF Power Source Circuit Intermittent

-

P06D61C

Generator Control Module Offset Power Circuit Voltage Out of Range

Hybrid system stopped

P0A0011

Motor Electronics Coolant Temperature Sensor Circuit Short to Ground

Normal driving

P0A0015

Motor Electronics Coolant Temperature Sensor Circuit Short to Battery or Open

Normal driving

P0A001C

Motor Electronics Coolant Temperature Sensor Circuit Voltage Out of Range

Normal driving

P0A1A47

Generator Control Module Watchdog / Safety MC Failure

  • Greatly reduced output power
  • Driving range is limited
  • Engine always stopped

P0A1A49

Generator Control Module Internal Electronic Failure

  • Greatly reduced output power
  • Driving range is limited
  • Engine always stopped

P0A1B1F

Generator Control Module Circuit Intermittent

Hybrid system stopped

P0A1B47

Drive Motor "A" Control Module Watchdog / Safety MC Failure

  • Greatly reduced output power
  • Driving in reverse not possible
  • Driving range is limited
  • Engine used while driving and engine speed becomes high

P0A1B49

Drive Motor "A" Control Module Internal Electronic Failure

  • Greatly reduced output power
  • Driving in reverse not possible
  • Driving range is limited
  • Engine used while driving and engine speed becomes high

P0A1B94

Drive Motor "A" Control Module Unexpected Operation

  1. Normal driving
  2. Hybrid system stopped when malfunction continues

P0A1C47

Drive Motor "B" Control Module Watchdog / Safety MCU Failure

AWD stopped

P0A1C49

Drive Motor "B" Control Module Internal Electronic Failure

AWD stopped

P0A2A11

Drive Motor "A" Temperature Sensor Circuit Short to Ground

Normal driving

P0A2A15

Drive Motor "A" Temperature Sensor Circuit Short to Auxiliary Battery or Open

Normal driving

P0A2A1C

Drive Motor "A" Temperature Sensor Voltage Out of Range

Normal driving

P0A2A1F

Drive Motor "A" Temperature Sensor Circuit Intermittent

Normal driving

P0A3611

Generator Temperature Sensor Circuit Short to Ground

Normal driving

P0A3615

Generator Temperature Sensor Circuit Short to Auxiliary Battery or Open

Normal driving

P0A361C

Generator Temperature Sensor Voltage Out of Range

Normal driving

P0A361F

Generator Temperature Sensor Circuit Intermittent

Normal driving

P0A3F16

Drive Motor "A" Position Sensor Circuit Voltage Below Threshold

  • Greatly reduced output power
  • Driving in reverse not possible
  • Driving range is limited
  • Engine used while driving and engine speed becomes high

P0A3F1F

Drive Motor "A" Position Sensor Circuit Intermittent

-

P0A3F21

Drive Motor "A" Position Sensor Signal Amplitude < Minimum

  • Greatly reduced output power
  • Driving in reverse not possible
  • Driving range is limited
  • Engine used while driving and engine speed becomes high

P0A3F22

Drive Motor "A" Position Sensor Signal Amplitude > Maximum

  • Greatly reduced output power
  • Driving in reverse not possible
  • Driving range is limited
  • Engine used while driving and engine speed becomes high

P0A4516

Drive Motor "B" Position Sensor Circuit Voltage Below Threshold

  1. AWD stopped
  2. Malfunction continues
    • Hybrid system stopped

P0A451F

Drive Motor "B" Position Sensor Circuit Intermittent

-

P0A4521

Drive Motor "B" Position Sensor Signal Amplitude < Minimum

  1. AWD stopped
  2. Malfunction continues
    • Hybrid system stopped

P0A4522

Drive Motor "B" Position Sensor Signal Amplitude > Maximum

  1. AWD stopped
  2. Malfunction continues
    • Hybrid system stopped

P0A4B16

Generator Position Sensor Circuit Voltage Below Threshold

  • Reduced output power
  • Engine used while driving and engine speed becomes high
  • Driving range is limited when driving with engine stopped

P0A4B1F

Generator Position Sensor Circuit Intermittent

-

P0A4B21

Generator Position Sensor Signal Amplitude < Minimum

  • Reduced output power
  • Engine used while driving and engine speed becomes high
  • Driving range is limited when driving with engine stopped

P0A4B22

Generator Position Sensor Signal Amplitude > Maximum

  • Reduced output power
  • Engine used while driving and engine speed becomes high
  • Driving range is limited when driving with engine stopped

P0A6012

Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery

Normal driving

P0A6014

Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open

Normal driving

P0A601C

Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range

Normal driving

P0A601F

Drive Motor "A" Phase V Current (High Resolution) Circuit Intermittent

-

P0A6312

Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery

Normal driving

P0A6314

Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open

Normal driving

P0A631C

Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range

Normal driving

P0A631F

Drive Motor "A" Phase W Current (High Resolution) Circuit Intermittent

-

P0A6912

Drive Motor "B" Phase V Current(High Resolution) Circuit Short to Battery

Normal driving

P0A6914

Drive Motor "B" Phase V Current(High Resolution) Circuit Short to Ground or Open

Normal driving

P0A691C

Drive Motor "B" Phase V Current(High Resolution) Circuit Voltage Out of Range

Normal driving

P0A691F

Drive Motor "B" Phase V Current(High Resolution) Circuit Intermittent

-

P0A6C12

Drive Motor "B" Phase W Current(High Resolution) Circuit Short to Battery

Normal driving

P0A6C14

Drive Motor "B" Phase W Current(High Resolution) Circuit Short to Ground or Open

Normal driving

P0A6C1C

Drive Motor "B" Phase W Current(High Resolution) Circuit Voltage Out of Range

Normal driving

P0A6C1F

Drive Motor "B" Phase W Current(High Resolution) Circuit Intermittent

-

P0A7872

Drive Motor "A" Inverter Actuator Stuck Open

  • Greatly reduced output power
  • Driving range is limited
  • Engine used while driving and engine speed becomes high

P0A7873

Drive Motor "A" Inverter Actuator Stuck Closed

  • Greatly reduced output power
  • Driving in reverse not possible
  • Driving range is limited
  • Engine used while driving and engine speed becomes high

P0A789E

Drive Motor "A" Inverter Stuck On

  • Greatly reduced output power
  • Driving in reverse not possible
  • Driving range is limited
  • Engine used while driving and engine speed becomes high

P0A7972

Drive Motor "B" Inverter Actuator Stuck Open

  1. AWD stopped
  2. Malfunction continues
    • Hybrid system stopped

P0A7973

Drive Motor "B" Inverter Actuator Stuck Closed

  1. AWD stopped
  2. Malfunction continues
    • Hybrid system stopped

P0A799E

Drive Motor "B" Inverter Stuck On

  1. AWD stopped
  2. Malfunction continues
    • Hybrid system stopped

P0A7A72

Generator Inverter Actuator Stuck Open

  • Reduced output power
  • Engine used while driving and engine speed becomes high
  • Driving range is limited when driving with engine stopped

P0A7A73

Generator Inverter Actuator Stuck Closed

  1. Normal driving
  2. Malfunction continues
    • Reduced output power
    • Driving range is limited
    • Engine always stopped
  3. Hybrid system stopped when malfunction continues

P0A7A9E

Generator Inverter Stuck On

  • Reduced output power
  • Driving range is limited
  • Engine always stopped

P0A9000

Drive Motor "A" Performance

  • Greatly reduced output power
  • Driving in reverse not possible
  • Driving range is limited
  • Engine used while driving and engine speed becomes high

P0A9100

Drive Motor "B" Performance

  1. AWD stopped
  2. Malfunction continues
    • Hybrid system stopped

P0A9200

Hybrid/EV Generator Performance

  • Reduced output power
  • Engine used while driving and engine speed becomes high
  • Driving range is limited when driving with engine stopped

P0A949E

DC/DC Converter Stuck On

  • Reduced output power
  • Driving range is limited
  • Engine not stopped

P0AED11

Drive Motor Inverter Temperature Sensor "A" Circuit Short to Ground

Normal driving

P0AED15

Drive Motor Inverter Temperature Sensor "A" Circuit Short to Battery or Open

Normal driving

P0AED1C

Drive Motor Inverter Temperature Sensor "A" Circuit Voltage Out of Range

Normal driving

P0AF211

Drive Motor Inverter Temperature Sensor "B" Circuit Short to Ground

Normal driving

P0AF215

Drive Motor Inverter Temperature Sensor "B" Circuit Short to Battery or Open

Normal driving

P0AF21C

Drive Motor Inverter Temperature Sensor "B" Circuit Voltage Out of Range

Normal driving

P0BCC11

Generator Inverter Temperature Sensor Circuit Short to Ground

Normal driving

P0BCC15

Generator Inverter Temperature Sensor Circuit Short to Battery or Open

Normal driving

P0BCC1C

Generator Inverter Temperature Sensor Circuit Voltage Out of Range

Normal driving

P0BE512

Drive Motor "A" Phase U Current Sensor Circuit Short to Battery

  • Greatly reduced output power
  • Driving in reverse not possible
  • Driving range is limited
  • Engine used while driving and engine speed becomes high

P0BE514

Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open

  • Greatly reduced output power
  • Driving in reverse not possible
  • Driving range is limited
  • Engine used while driving and engine speed becomes high

P0BE51F

Drive Motor "A" Phase U Current Sensor Circuit Intermittent

-

P0BE528

Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure

  • Greatly reduced output power
  • Driving in reverse not possible
  • Driving range is limited
  • Engine used while driving and engine speed becomes high

P0BE912

Drive Motor "A" Phase V Current Sensor Circuit Short to Battery

  • Greatly reduced output power
  • Driving in reverse not possible
  • Driving range is limited
  • Engine used while driving and engine speed becomes high

P0BE914

Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open

  • Greatly reduced output power
  • Driving in reverse not possible
  • Driving range is limited
  • Engine used while driving and engine speed becomes high

P0BE91F

Drive Motor "A" Phase V Current Sensor Circuit Intermittent

-

P0BE928

Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure

  • Greatly reduced output power
  • Driving in reverse not possible
  • Driving range is limited
  • Engine used while driving and engine speed becomes high

P0BED12

Drive Motor "A" Phase W Current Sensor Circuit Short to Battery

  • Greatly reduced output power
  • Driving in reverse not possible
  • Driving range is limited
  • Engine used while driving and engine speed becomes high

P0BED14

Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open

  • Greatly reduced output power
  • Driving in reverse not possible
  • Driving range is limited
  • Engine used while driving and engine speed becomes high

P0BED1F

Drive Motor "A" Phase W Current Sensor Circuit Intermittent

-

P0BED28

Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure

  • Greatly reduced output power
  • Driving in reverse not possible
  • Driving range is limited
  • Engine used while driving and engine speed becomes high

P0BF112

Drive Motor "B" Phase U Current Sensor Circuit Short to Battery

  1. AWD stopped
  2. Malfunction continues
    • Hybrid system stopped

P0BF114

Drive Motor "B" Phase U Current Sensor Circuit Short to Ground or Open

  1. AWD stopped
  2. Malfunction continues
    • Hybrid system stopped

P0BF11F

Drive Motor "B" Phase U Current Sensor Circuit Intermittent

-

P0BF128

Drive Motor "B" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure

  1. AWD stopped
  2. Malfunction continues
    • Hybrid system stopped

P0BF512

Drive Motor "B" Phase V Current Sensor Circuit Short to Battery

  1. AWD stopped
  2. Malfunction continues
    • Hybrid system stopped

P0BF514

Drive Motor "B" Phase V Current Sensor Circuit Short to Ground or Open

  1. AWD stopped
  2. Malfunction continues
    • Hybrid system stopped

P0BF51F

Drive Motor "B" Phase V Current Sensor Circuit Intermittent

-

P0BF528

Drive Motor "B" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure

  1. AWD stopped
  2. Malfunction continues
    • Hybrid system stopped

P0BF912

Drive Motor "B" Phase W Current Sensor Circuit Short to Battery

  1. AWD stopped
  2. Malfunction continues
    • Hybrid system stopped

P0BF914

Drive Motor "B" Phase W Current Sensor Circuit Short to Ground or Open

  1. AWD stopped
  2. Malfunction continues
    • Hybrid system stopped

P0BF91F

Drive Motor "B" Phase W Current Sensor Circuit Intermittent

-

P0BF928

Drive Motor "B" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure

  1. AWD stopped
  2. Malfunction continues
    • Hybrid system stopped

P0BFD62

Drive Motor "A" Phase U-V-W Current Sensor Signal Compare Failure

  • Greatly reduced output power
  • Driving in reverse not possible
  • Driving range is limited
  • Engine used while driving and engine speed becomes high

P0BFE62

Drive Motor "B" Phase U-V-W Current Sensor Signal Compare Failure

  1. AWD stopped
  2. Malfunction continues
    • Hybrid system stopped

P0BFF1D

Drive Motor "A" Circuit Current Out of Range

  • Greatly reduced output power
  • Driving in reverse not possible
  • Driving range is limited
  • Engine used while driving and engine speed becomes high

P0C021D

Drive Motor "B" System Circuit Current Out of Range

  1. AWD stopped
  2. Malfunction continues
    • Hybrid system stopped

P0C1900

Drive Motor "A" Execution Torque Performance

  • Greatly reduced output power
  • Driving in reverse not possible
  • Driving range is limited
  • Engine used while driving and engine speed becomes high

P0C1A00

Drive Motor "B" Execution Torque Performance

  1. AWD stopped
  2. Malfunction continues
    • Hybrid system stopped

P0C3811

DC/DC Converter Temperature Sensor "A" Circuit Short to Ground

Normal driving

P0C3815

DC/DC Converter Temperature Sensor "A" Circuit Short to Battery or Open

Normal driving

P0C381C

DC/DC Converter Temperature Sensor "A" Circuit Voltage Out of Range

Normal driving

P0C3D11

DC/DC Converter Temperature Sensor "B" Circuit Short to Ground

Normal driving

P0C3D15

DC/DC Converter Temperature Sensor "B" Circuit Short to Battery or Open

Normal driving

P0C3D1C

DC/DC Converter Temperature Sensor "B" Circuit Voltage Out of Range

Normal driving

P0C5013

Drive Motor "A" Position Sensor Circuit "A" Circuit Open

  • Greatly reduced output power
  • Driving in reverse not possible
  • Driving range is limited
  • Engine used while driving and engine speed becomes high

P0C5016

Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold

  • Greatly reduced output power
  • Driving in reverse not possible
  • Driving range is limited
  • Engine used while driving and engine speed becomes high

P0C5017

Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold

  • Greatly reduced output power
  • Driving in reverse not possible
  • Driving range is limited
  • Engine used while driving and engine speed becomes high

P0C501F

Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent

-

P0C5513

Drive Motor "B" Position Sensor Circuit "A" Circuit Open

  1. AWD stopped
  2. Malfunction continues
    • Hybrid system stopped

P0C5516

Drive Motor "B" Position Sensor Circuit "A" Circuit Voltage Below Threshold

  1. AWD stopped
  2. Malfunction continues
    • Hybrid system stopped

P0C5517

Drive Motor "B" Position Sensor Circuit "A" Circuit Voltage Above Threshold

  1. AWD stopped
  2. Malfunction continues
    • Hybrid system stopped

P0C551F

Drive Motor "B" Position Sensor Circuit "A" Circuit Intermittent

-

P0C5A13

Drive Motor "A" Position Sensor Circuit "B" Circuit Open

  • Greatly reduced output power
  • Driving in reverse not possible
  • Driving range is limited
  • Engine used while driving and engine speed becomes high

P0C5A16

Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold

  • Greatly reduced output power
  • Driving in reverse not possible
  • Driving range is limited
  • Engine used while driving and engine speed becomes high

P0C5A17

Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold

  • Greatly reduced output power
  • Driving in reverse not possible
  • Driving range is limited
  • Engine used while driving and engine speed becomes high

P0C5A1F

Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent

-

P0C5F13

Drive Motor "B" Position Sensor Circuit "B" Circuit Open

  1. AWD stopped
  2. Malfunction continues
    • Hybrid system stopped

P0C5F16

Drive Motor "B" Position Sensor Circuit "B" Circuit Voltage Below Threshold

  1. AWD stopped
  2. Malfunction continues
    • Hybrid system stopped

P0C5F17

Drive Motor "B" Position Sensor Circuit "B" Circuit Voltage Above Threshold

  1. AWD stopped
  2. Malfunction continues
    • Hybrid system stopped

P0C5F1F

Drive Motor "B" Position Sensor Circuit "B" Circuit Intermittent

-

P0C6413

Generator Position Sensor Circuit "A" Circuit Open

  • Reduced output power
  • Engine used while driving and engine speed becomes high
  • Driving range is limited when driving with engine stopped

P0C6416

Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold

  • Reduced output power
  • Engine used while driving and engine speed becomes high
  • Driving range is limited when driving with engine stopped

P0C6417

Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold

  • Reduced output power
  • Engine used while driving and engine speed becomes high
  • Driving range is limited when driving with engine stopped

P0C641F

Generator Position Sensor Circuit "A" Circuit Intermittent

-

P0C6913

Generator Position Sensor Circuit "B" Circuit Open

  • Reduced output power
  • Engine used while driving and engine speed becomes high
  • Driving range is limited when driving with engine stopped

P0C6916

Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold

  • Reduced output power
  • Engine used while driving and engine speed becomes high
  • Driving range is limited when driving with engine stopped

P0C6917

Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold

  • Reduced output power
  • Engine used while driving and engine speed becomes high
  • Driving range is limited when driving with engine stopped

P0C691F

Generator Position Sensor Circuit "B" Circuit Intermittent

-

P0C7917

Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold

  1. Normal driving
  2. Hybrid system stopped when malfunction continues

P0CA300

DC/DC Converter Step Up Voltage Performance

  • Greatly reduced output power
  • Driving range is limited
  • Engine always stopped

P0D2D16

Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold

Reduced output power

P0D2D17

Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold

Reduced output power

P0D2D1F

Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Intermittent

-

P0D3319

DC/DC Converter Circuit Current Above Threshold

  • Reduced output power
  • Driving range is limited
  • Engine not stopped

P0DFA62

Generator Phase U-V-W Current Sensor Signal Compare Failure

  • Reduced output power
  • Engine used while driving and engine speed becomes high
  • Driving range is limited when driving with engine stopped

P0E0012

Generator Phase U Current Sensor Circuit Short to Battery

  • Reduced output power
  • Driving range is limited
  • Engine always stopped

P0E0014

Generator Phase U Current Sensor Circuit Short to Ground or Open

  • Reduced output power
  • Driving range is limited
  • Engine always stopped

P0E001F

Generator Phase U Current Sensor Circuit Intermittent

-

P0E0028

Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure

  • Reduced output power
  • Driving range is limited
  • Engine always stopped

P0E0412

Generator Phase V Current Sensor Circuit Short to Battery

  • Reduced output power
  • Driving range is limited
  • Engine always stopped

P0E0414

Generator Phase V Current Sensor Circuit Short to Ground or Open

  • Reduced output power
  • Driving range is limited
  • Engine always stopped

P0E041F

Generator Phase V Current Sensor Circuit Intermittent

-

P0E0428

Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure

  • Reduced output power
  • Driving range is limited
  • Engine always stopped

P0E0812

Generator Phase W Current Sensor Circuit Short to Battery

  • Reduced output power
  • Driving range is limited
  • Engine always stopped

P0E0814

Generator Phase W Current Sensor Circuit Short to Ground or Open

  • Reduced output power
  • Driving range is limited
  • Engine always stopped

P0E081F

Generator Phase W Current Sensor Circuit Intermittent

-

P0E0828

Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure

  • Reduced output power
  • Driving range is limited
  • Engine always stopped

P0E3116

DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Below Threshold

Reduced output power

P0E3117

DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Above Threshold

Reduced output power

P0E311F

DC/DC Converter Voltage Sensor "A" (VL) Circuit Intermittent

-

P0E5111

DC/DC Converter Current Sensor Circuit Short to Ground

Reduced output power

P0E5115

DC/DC Converter Current Sensor Circuit Short to Battery or Open

Reduced output power

P0E511F

DC/DC Converter Current Sensor Circuit Intermittent

-

P0E5128

DC/DC Converter Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure

Reduced output power

P0E512A

DC/DC Converter Current Sensor Signal Stuck In Range

Reduced output power

P0E5717

DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Above Threshold

  • Reduced output power
  • Driving range is limited
  • Engine always stopped

P0E7100

Generator Execution Torque Performance

  • Reduced output power
  • Engine used while driving and engine speed becomes high
  • Driving range is limited when driving with engine stopped

P19F81C

Generator Control Module Offset Power Circuit Voltage Out of Range

  • Reduced output power
  • Engine used while driving and engine speed becomes high
  • Driving range is limited when driving with engine stopped

P19F91C

Drive Motor "B" Control Module Offset Power Circuit Voltage Out of Range

AWD stopped

P1C2A1C

Generator A/D Converter Circuit Circuit Voltage Out of Range

  • Greatly reduced output power
  • Driving range is limited
  • Engine always stopped

P1C2A49

Generator A/D Converter Circuit Internal Electronic Failure

  • Greatly reduced output power
  • Driving range is limited
  • Engine always stopped

P1C2A71

Generator A/D Converter Circuit Actuator Stuck

  • Greatly reduced output power
  • Driving range is limited
  • Engine always stopped

P1C2B1C

Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range

  • Greatly reduced output power
  • Driving in reverse not possible
  • Driving range is limited
  • Engine used while driving and engine speed becomes high

P1C2B49

Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure

  • Greatly reduced output power
  • Driving in reverse not possible
  • Driving range is limited
  • Engine used while driving and engine speed becomes high

P1C2B71

Drive Motor "A" Control Module A/D Converter Circuit Actuator Stuck

  • Greatly reduced output power
  • Driving in reverse not possible
  • Driving range is limited
  • Engine used while driving and engine speed becomes high

P1C2C1C

Drive Motor "B" Control Module AD Converter Circuit Voltage Out of Range

AWD stopped

P1C2C49

Drive Motor "B" Control Module AD Converter Circuit Internal Electronic Failure

AWD stopped

P1C2C71

Drive Motor "B" Control Module A/D Converter Circuit Actuator Stuck

AWD stopped

P1C5D19

Drive Motor "A" Inverter Circuit Current Above Threshold

  • Greatly reduced output power
  • Driving in reverse not possible
  • Driving range is limited
  • Engine used while driving and engine speed becomes high

P1C5E19

Drive Motor "B" Inverter Circuit Current Above Threshold

  1. AWD stopped
  2. Malfunction continues
    • Hybrid system stopped

P1C5F19

Generator Inverter Circuit Current Above Threshold

  1. Normal driving
  2. Malfunction continues
    • Reduced output power
    • Driving range is limited
    • Engine always stopped
  3. Hybrid system stopped when malfunction continues

P1C601F

Generator Control Module Position Sensor REF Power Source Circuit Intermittent

-

P1C621F

Generator Control Module Offset Power Circuit Intermittent

-

P1C641F

Generator Control Module Circuit Intermittent

-

P1C651F

Generator Control Module Circuit Intermittent

-

P1C661F

Drive Motor "B" Control Module Circuit Intermittent

-

P1C671F

Drive Motor "A" Phase U-V-W Current Sensor Circuit Intermittent

-

P1C681F

Drive Motor "B" Phase U-V-W Current Sensor Circuit Intermittent

-

P1C691F

Generator Phase U-V-W Current Sensor Circuit Intermittent

-

P1CA51D

Hybrid/EV Generator Circuit Current Out of Range

  • Reduced output power
  • Engine used while driving and engine speed becomes high
  • Driving range is limited when driving with engine stopped

P1CAC49

Generator Position Sensor Internal Electronic Failure

  • Reduced output power
  • Engine used while driving and engine speed becomes high
  • Driving range is limited when driving with engine stopped

P1CAD49

Drive Motor "A" Position Sensor Internal Electronic Failure

  • Greatly reduced output power
  • Driving in reverse not possible
  • Driving range is limited
  • Engine used while driving and engine speed becomes high

P1CAE49

Drive Motor "B" Position Sensor Internal Electronic Failure

AWD stopped

P1CAF38

Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect

  • Reduced output power
  • Engine used while driving and engine speed becomes high
  • Driving range is limited when driving with engine stopped

P1CB038

Drive Motor "A" Position Sensor REF Signal Frequency Incorrect

  • Greatly reduced output power
  • Driving in reverse not possible
  • Driving range is limited
  • Engine used while driving and engine speed becomes high

P1CB138

Drive Motor "B" Position Sensor REF Signal Frequency Incorrect

  1. AWD stopped
  2. Malfunction continues
    • Hybrid system stopped

P1CB59E

DC/DC Converter Voltage Sensor "A" (VL) Stuck On

  • Reduced output power
  • Driving range is limited
  • Engine not stopped

P1CB69E

Drive Motor "A" Inverter Voltage Sensor (VH) Stuck On

Reduced output power

P1CFF62

Hybrid/EV Battery Current/DC/DC Converter Current Signal Compare Failure

Reduced output power

P26DF1C

Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range

  • Reduced output power
  • Engine used while driving and engine speed becomes high
  • Driving range is limited when driving with engine stopped

P26DF1F

Generator Control Module Position Sensor REF Power Source Circuit Intermittent

-

P274A11

Transmission Fluid Temperature Sensor "C" Circuit Short to Ground

Normal driving

P274A15

Transmission Fluid Temperature Sensor "C" Circuit Short to Auxiliary Batteryor Open

Normal driving

P274A1C

Transmission Fluid Temperature Sensor "C" Voltage Out of Range

Normal driving

P274A1F

Transmission Fluid Temperature Sensor "C" Circuit Intermittent

Normal driving

P310A1F

Communication Error from Drive Motor "B" to Drive Motor "A" Circuit Intermittent

AWD stopped

P310A83

Communication Error from Drive Motor "B" to Drive Motor "A" Value of Signal Protection Calculation Incorrect

AWD stopped

P310A86

Communication Error from Drive Motor "B" to Drive Motor "A" Signal (Some Circuit Quantity, Reported via Serial Data) Invalid

AWD stopped

P310A87

Communication Error from Drive Motor "B" to Drive Motor "A" Missing Message

AWD stopped

P310B1F

Communication Error from Drive Motor "A" to Drive Motor "B" Circuit Intermittent

-

P310B83

Communication Error from Drive Motor "A" to Drive Motor "B" Value of Signal Protection Calculation Incorrect

AWD stopped

P310B86

Communication Error from Drive Motor "A" to Drive Motor "B" Signal (Some Circuit Quantity, Reported via Serial Data) Invalid

AWD stopped

P310B87

Communication Error from Drive Motor "A" to Drive Motor "B" Missing Message

AWD stopped

P31241F

Lost Communication between Drive Motor "A" and HV/EV ECU Circuit Intermittent

-

P313383

Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect

  • Greatly reduced output power
  • Driving range is limited
  • Engine always stopped

P313386

Communication Error from Generator to Drive Motor "A" Signal Invalid

  • Greatly reduced output power
  • Driving range is limited
  • Engine always stopped

P313387

Communication Error from Generator to Drive Motor "A" Missing Message

  • Greatly reduced output power
  • Driving range is limited
  • Engine always stopped

P313483

Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect

  • Greatly reduced output power
  • Driving range is limited
  • Engine always stopped

P313486

Communication Error from Drive Motor "A" to Generator Signal Invalid

  • Greatly reduced output power
  • Driving range is limited
  • Engine always stopped

P313487

Communication Error from Drive Motor "A" to Generator Missing Message

  • Greatly reduced output power
  • Driving range is limited
  • Engine always stopped

P314F1F

DC/DC Converter Voltage Sensor "A" (VL) Circuit Intermittent

Reduced output power

P31531D

DC/DC Converter Current Sensor Circuit Current Out of Range

Reduced output power

P32BF1F

Lost Communication between Drive Motor "A" and "B" (Drive Motor "A") Circuit Intermittent

-

P32BF83

Lost Communication between Drive Motor "A" and "B" (Drive Motor "A") Value of Signal Protection Calculation Incorrect

AWD stopped

P32BF86

Lost Communication between Drive Motor "A" and "B" (Drive Motor "A") Signal (Some Circuit Quantity, Reported via Serial Data) Invalid

AWD stopped

P32BF87

Lost Communication between Drive Motor "A" and "B" (Drive Motor "A") Missing Message

AWD stopped

P32CF1F

Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Circuit Intermittent

-

P32CF83

Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Value of Signal Protection Calculation Incorrect

AWD stopped

P32CF86

Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Signal (Some Circuit Quantity, Reported via Serial Data) Invalid

AWD stopped

P32CF87

Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Missing Message

AWD stopped

U010087

Lost Communication With ECM/PCM "A" Missing Message

Normal driving

U029387

Lost Communication With Hybrid Powertrain Control Module Missing Message

Normal driving

U117008

Lost Communication with Brake System Control Module (ch2) Bus Signal / Message Failure

Normal driving

U117087

Lost Communication With Brake System Control Module(ch2) Missing Message

Normal driving

U11B300

Lost Communication with Hybrid/EV Powertrain Control Module (ch5) (System 2) Missing Message

  • Reduced output power
  • Engine not stopped

U11B387

Lost Communication with Hybrid/EV Powertrain Control Module (ch5) Missing Message

  • Reduced output power
  • Engine not stopped

    READ NEXT:

     Data List / Active Test

    DATA LIST / ACTIVE TEST DATA LIST NOTICE: Some Data List values may vary significantly if there are slight differences in the environment in which the vehicle is operating when measurements a

     Diagnostic Trouble Code Chart

    DIAGNOSTIC TROUBLE CODE CHART Motor Generator Control System DTC No. Detection Item MIL Warning Indicate Note Link P033506 Crankshaft Position Sensor "A" Algorithm

     Crankshaft Position Sensor "A" Algorithm Based Failure (P033506,P033562)

    DESCRIPTION The motor generator control ECU (MG ECU) (built into the inverter with converter assembly) compares the engine speed value calculated based on the crankshaft position signal input from the

    SEE MORE:

     Fuel information

    You must only use unleaded gasoline. Select octane rating of 87 (Research Octane Number 91) or higher. Use of unleaded gasoline with an octane rating lower than 87 may result in engine knocking. Persistent knocking can lead to engine damage. At minimum, the gasoline you use should meet the specifi

     VEHICLE CONTROL HISTORY (RoB)

    VEHICLE CONTROL HISTORY (RoB) NOTICE: When checking the vehicle control history, first store the output history and then check the history. CHECK VEHICLE CONTROL HISTORY (a) Following the instructions on the GTS, display the vehicle control history (RoB) check screen and read the codes. Bod

    © 2020-2024 Copyright www.tcorollacross.com