DESCRIPTION
The HV battery is composed of 60 cells (3.7 V each) in series. The battery ECU assembly monitors the capacity of each HV battery cell to detect malfunctions of the HV battery.
DTC No. | Detection Item |
DTC Detection Condition |
Trouble Area | MIL |
Warning Indicate | Note |
---|---|---|---|---|---|---|
P33E600 | Hybrid/EV Battery Stack 1 Capacity Decline |
Full charge capacity of the No. 1 HV supply stack sub-assembly is less than the specified value. (1 trip detection logic) |
HV battery | Does not come on |
Master Warning Light: Comes on |
SAE Code: P33E6 |
P33E700 | Hybrid/EV Battery Stack 2 Capacity Decline |
Full charge capacity of the No. 2 HV supply stack sub-assembly is less than the specified value. (1 trip detection logic) |
HV battery | Does not come on |
Master Warning Light: Comes on |
SAE Code: P33E7 |
CONFIRMATION DRIVING PATTERN
HINT:
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click here
(This DTC may not be stored if the vehicle is stopped or being driven at a constant speed.)
HINT:
CAUTION / NOTICE / HINT
CAUTION:
Refer to the precautions before inspecting high voltage circuit.
Click here
NOTICE:
Click here
HINT:
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click here
PROCEDURE
1. | CHECK DTC OUTPUT (HV BATTERY, HYBRID CONTROL) |
(a) Check for DTCs.
Powertrain > HV Battery > Trouble Codes Powertrain > Hybrid Control > Trouble Codes
Result | Proceed to |
---|---|
"P33E600 or P33E700" only is output, or DTCs except the ones in the table below are also output. |
A |
DTCs of hybrid battery system in the table below are output. |
B |
DTCs of hybrid control system in the table below are output. |
C |
System | Relevant DTC | |
---|---|---|
Hybrid battery system |
P060A47 | Hybrid/EV Battery Energy Control Module Monitoring Processor Watchdog / Safety MCU Failure |
P060B49 | Hybrid/EV Battery Energy Control Module A/D Processing Internal Electronic Failure | |
P060687 | Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Missing Message | |
Hybrid control system |
P0A1F94 | Hybrid/EV Battery Energy Control Module Unexpected Operation |
(b) Turn the ignition switch off.
A | REPLACE HV SUPPLY BATTERY ASSEMBLY |
B | GO TO DTC CHART (HYBRID BATTERY SYSTEM) |
C | GO TO DTC CHART (HYBRID CONTROL SYSTEM) |