Toyota Corolla Cross Owners & Service Manuals

Toyota Corolla Cross: Air Vent cannot be Switched

DESCRIPTION

If the air outlet mode does not change even though the air outlet display changes, the following factors may be the cause.

Symptom

Factor

Air outlet mode cannot be changed

  • (Air outlet display changes)
  • No. 1 air conditioning radiator damper servo sub-assembly malfunction
  • No. 2 air conditioning radiator damper servo sub-assembly malfunction
  • Damper link disconnection
  • Air conditioner unit assembly malfunction

PROCEDURE

1.

CHECK AIR OUTLET SERVO MOTOR

(a) Confirm for which seat the air outlet mode cannot be changed.

Result

Proceed to

The air outlet mode for the front seats cannot be changed

A

The air outlet mode for the rear seats cannot be changed

B

B

GO TO STEP 4

A

2.

CHECK NO. 1 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY

(a) Check that the No. 1 air conditioning radiator damper servo sub-assembly is installed correctly.

OK:

The No. 1 air conditioning radiator damper servo sub-assembly is installed correctly.

NG

INSTALL NO. 1 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY

OK

3.

CHECK FOR DTC

(a) Check for DTCs.

Body Electrical > Air Conditioner > Trouble Codes

Result

Proceed to

B140287 and B14037F are not output

A

B140287 is output

B

B14037F is output

C

A

REPLACE AIR CONDITIONING RADIATOR ASSEMBLY

B

GO TO DTC B140287

C

GO TO DTC B14037F

4.

CHECK NO. 2 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY

(a) Check that the No. 2 air conditioning radiator damper servo sub-assembly is installed correctly.

OK:

The No. 2 air conditioning radiator damper servo sub-assembly is installed correctly.

NG

INSTALL NO. 2 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY

OK

5.

CHECK FOR DTC

(a) Check for DTCs.

Body Electrical > Air Conditioner > Trouble Codes

Result

Proceed to

B13AA87 and B13AB7F are not output

A

B13AA87 is output

B

B13AB7F is output

C

A

REPLACE AIR CONDITIONING RADIATOR ASSEMBLY

B

GO TO DTC B13AA87

C

GO TO DTC B13AB7F

    READ NEXT:

     Air Vent Temperature does not Change and Right Vent is Different from Left and Vice Versa (Same Left/Right Temperature Setting)

    DESCRIPTION If the temperature of the air that blows from the left and right front registers differs, even though the same temperature is set for both sides, the following factors may be the cause.

     No Warm Air Comes Out

    DESCRIPTION If cool air blows from the registers regardless of the temperature setting of the air conditioning system, the following factors may be the cause. Symptom Factor No wa

     Air Conditioning System (for Gasoline Model With Manual Air Conditioning System)

    SEE MORE:

     Removal

    REMOVAL CAUTION / NOTICE / HINT COMPONENTS (REMOVAL) Procedure Part Name Code 1 PRECAUTION - - - 2 DISCONNECT CABLE FROM NEGATIVE AUXILIARY BATTERY TERMINAL - - - - 3 TONNEAU COVER ASSEMBLY 64910J

     Installation

    INSTALLATION CAUTION / NOTICE / HINT COMPONENTS (INSTALLATION) Procedure Part Name Code 1 AUTOMATIC LIGHT CONTROL SENSOR 89120A - - - 2 INSTRUMENT PANEL SAFETY PAD ASSEMBLY - - - - PROCEDURE 1. INSTALL AUTOMATIC LI

    © 2020-2024 Copyright www.tcorollacross.com