ON-VEHICLE INSPECTION

PROCEDURE

1. INSPECT ACCELERATOR PEDAL SENSOR ASSEMBLY

(a) Connect the GTS to the DLC3.

(b) Turn the power switch on (IG).

(c) Turn the GTS on.

(d) Enter the following menus: Powertrain / Hybrid Control / Data List / Accelerator Position Sensor No. 1 Voltage %, Accelerator Position Sensor No. 2 Voltage %.

Powertrain > Hybrid Control > Data List

Tester Display

Accelerator Position Sensor No.1 Voltage %

Accelerator Position Sensor No.2 Voltage %

(e) Read the Data List.

Tester Display

Accelerator Pedal Condition

Specified Condition

Accelerator Position Sensor No. 1 Voltage %

Not depressed

10 to 22%

Fully depressed

52 to 90%

Not depressed → Fully depressed → Not depressed (Accelerator pedal should be operated slowly)

Value changes progressively

Accelerator Position Sensor No. 2 Voltage %

Not depressed

24 to 40%

Fully depressed

68 to 99%

Not depressed → Fully depressed → Not depressed (Accelerator pedal should be operated slowly)

Value changes progressively

    READ NEXT:

     Removal

    REMOVAL CAUTION / NOTICE / HINT COMPONENTS (REMOVAL) Procedure Part Name Code 1 NO. 1 INSTRUMENT PANEL UNDER COVER SUB-ASSEMBLY 55606 - - -

     Installation

    INSTALLATION CAUTION / NOTICE / HINT COMPONENTS (INSTALLATION) Procedure Part Name Code 1 ACCELERATOR PEDAL SENSOR ASSEMBLY 78110K

     Battery Blower

    SEE MORE:

     Checking Monitor Status

    CHECKING MONITOR STATUS The purpose of the monitor result (mode 06) is to allow access to the results of on-board diagnostic monitoring tests of specific components/systems that are not continuously monitored. Examples are catalysts and evaporative emissions (EVAP) systems. The monitor result allo

     Drive Motor "A" Inverter Actuator Stuck Closed (P0A7873)

    DTC SUMMARY MALFUNCTION DESCRIPTION This DTC is stored when a short is detected in the inverter with converter assembly (motor inverter) or the hybrid vehicle transaxle assembly (motor (MG2)). The cause of this malfunction may be one of the following: Internal inverter malfunction Motor inver

    © 2020-2024 Copyright www.tcorollacross.com