DTC SUMMARY
MALFUNCTION DESCRIPTION
This DTC indicates that a large current flowed in the inverter generator. The cause of this malfunction may be one of the following:
Area | Main Malfunction Description |
---|---|
Hybrid vehicle transaxle assembly |
|
Resolver |
Open or short circuit in the generator resolver |
Inverter |
|
Inverter cooling system |
|
DESCRIPTION
For a description of the inverter.
Click here
DTC No. | Detection Item |
DTC Detection Condition |
Trouble Area | MIL |
Warning Indicate | Note |
---|---|---|---|---|---|---|
P0A7A9E | Generator Inverter Stuck On |
Generator inverter fail signal detected (circuit malfunction) (1 trip detection logic) |
| Comes on |
Master Warning: Comes on |
SAE Code: P0A7A |
P1C5F19 | Generator Inverter Circuit Current Above Threshold |
Generator inverter fail signal detected: A malfunction is detected in any of the generator components (generator inverter, generator (MG1), generator resolver, motor generator control ECU, etc.). (1 trip detection logic) |
| Comes on |
Master Warning: Comes on |
SAE Code: P1C5F |
MONITOR DESCRIPTION
If too much current is detected flowing through the generator inverter, the generator inverter transmits an inverter fail signal to the motor generator control ECU. Upon receiving this signal, the ECU will illuminate the MIL and store a DTC.
MONITOR STRATEGY
Related DTCs | P0A7A (INF P0A7A9E): GFIV detection (Circuit malfunction) P1C5F (INF P1C5F19): GFIV detection (Over current malfunction) |
Required sensors/components | Generator inverter |
Frequency of operation | Continuous |
Duration | TMC's intellectual property |
MIL operation | 1 driving cycle |
Sequence of operation | None |
TYPICAL ENABLING CONDITIONS
The monitor will run whenever the following DTCs are not stored |
TMC's intellectual property |
Other conditions belong to TMC's intellectual property |
- |
TYPICAL MALFUNCTION THRESHOLDS
TMC's intellectual property | - |
COMPONENT OPERATING RANGE
Motor generator control ECU | DTC P0A7A (INF P0A7A9E) is not detected DTC P1C5F (INF P1C5F19) is not detected |
CONFIRMATION DRIVING PATTERN
HINT:
Click here
Click here
HINT:
Check that there are no abnormalities (abnormal sounds, coolant leaks, etc.).
NOTICE:
As the state of charge of the HV battery may be low after driving in fail-safe mode, it will automatically be charged for 5 to 10 minutes with ignition switch ON (READY) after repairs have been performed.
HINT:
[*1] to [*5]: Normal judgment procedure.
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
HINT:
WIRING DIAGRAM
Refer to the wiring diagram for the Generator Resolver Circuit.
Click here
Refer to the wiring diagram for the Motor Resolver Circuit.
Click here
Refer to the wiring diagram for the Rear Motor Resolver Circuit.
Click here
Refer to the wiring diagram for the Generator High-voltage Circuit.
Click here
Refer to the wiring diagram for the Motor High-voltage Circuit.
Click here
Refer to the wiring diagram for the Rear Motor High-voltage Circuit.
Click here
Refer to the wiring diagram for the Inverter Low-voltage Circuit.
Click here
Refer to the wiring diagram for the Cooling System.
Click here
CAUTION / NOTICE / HINT
CAUTION:
Refer to the precautions before inspecting high voltage circuit.
Click here
NOTICE:
Click here
HINT:
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click here
HINT:
Malfunction Content | System |
Relevant DTC | |
---|---|---|---|
Insulation malfunction |
Hybrid control system |
P1C7C49 | Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure |
P1C7D49 | Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure | ||
P1C7E49 | Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure | ||
P1C7F49 | Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure | ||
P1C8049 | Hybrid/EV Battery Voltage System Isolation (Rear Motor Area) Internal Electronic Failure | ||
System main relay or high voltage circuit malfunction |
Hybrid control system |
P0AD911 | Hybrid/EV Battery Positive Contactor Circuit Short to Ground |
P0AD915 | Hybrid/EV Battery Positive Contactor Circuit Short to Auxiliary Battery or Open | ||
P0ADD11 | Hybrid/EV Battery Negative Contactor Circuit Short to Ground | ||
P0ADD15 | Hybrid/EV Battery Negative Contactor Circuit Short to Auxiliary Battery or Open | ||
P1C8449 | High Voltage Power Resource Circuit Short during Ready ON | ||
HV battery malfunction |
Hybrid control system |
P0A1F94 | Hybrid/EV Battery Energy Control Module Unexpected Operation |
P0ABF00 | Hybrid/EV Battery Current Sensor "A" Circuit Range/Performance | ||
P0B231C | Hybrid/EV Battery "A" Voltage Sensor Voltage Out of Range | ||
P31B300 | Hybrid/EV Battery Voltage High | ||
U011187 | Lost Communication with Hybrid/EV Battery Energy Control Module "A" Missing Message | ||
Hybrid battery system | P056014 |
System Voltage (BATT) Circuit Short to Ground or Open | |
P060629 | Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Signal Invalid | ||
P060687 | Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Missing Message | ||
P060A47 | Hybrid/EV Battery Energy Control Module Monitoring Processor Watchdog / Safety MCU Failure | ||
P060A87 | Hybrid/EV Battery Energy Control Module Processor from Monitoring Processor Missing Message | ||
P060B49 | Hybrid/EV Battery Energy Control Module A/D Processing Internal Electronic Failure | ||
P0ABF11 | Hybrid/EV Battery Current Sensor "A" Circuit Short to Ground | ||
P0ABF15 | Hybrid/EV Battery Current Sensor "A" Circuit Short to Auxiliary Battery or Open | ||
P0ABF28 | Hybrid/EV Battery Current Sensor "A" Signal Bias Level Out of Range / Zero Adjustment Failure | ||
P0ABF2A | Hybrid/EV Battery Current Sensor "A" Signal Stuck In Range | ||
P0B0E11 | Hybrid/EV Battery Current Sensor "B" Circuit Short to Ground | ||
P0B0E15 | Hybrid/EV Battery Current Sensor "B" Circuit Short to Auxiliary Battery or Open | ||
P0B1362 | Hybrid/EV Battery Current Sensor "A"/"B" Signal Compare Failure | ||
P0E2D00 | Hybrid/EV Battery Energy Control Module Hybrid/EV Battery Monitor Performance | ||
P1A001C | Hybrid Battery Stack 2 Cell Voltage Detection Voltage Out of Range | ||
P1A6017 | Hybrid/EV Battery Stack 2 Cell Circuit Voltage Above Threshold | ||
P1A6116 | Hybrid/EV Battery Stack 2 Cell Circuit Voltage Below Threshold | ||
P1A8100 | Hybrid/EV Battery Stack 1 Delta SOC High (Extreme) | ||
P1A8600 | Hybrid/EV Battery Stack 2 Delta SOC High (Extreme) | ||
P1AFD00 | Flying Capacitor Circuit Voltage Out of Range | ||
P1AFD1C | Flying Capacitor/Internal Control Module Hybrid/EV Battery Monitor Voltage Out of Range | ||
P1CBB12 | Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Auxiliary Battery | ||
P1CBB14 | Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Ground or Open | ||
P1CC81E | Hybrid/EV Battery Stack 1 Voltage Difference Out of Range | ||
P1CC91E | Hybrid/EV Battery Stack 2 Voltage Difference Out of Range | ||
P301A1C | Hybrid Battery Stack 1 Cell Voltage Detection Voltage Out of Range | ||
P31AA17 | Hybrid/EV Battery Stack 1 Cell Circuit Voltage Above Threshold | ||
P31AB16 | Hybrid/EV Battery Stack 1 Cell Circuit Voltage Below Threshold | ||
P33DA1E | Hybrid/EV Battery Stack 1 Circuit Resistance Out of Range | ||
P33DB1E | Hybrid/EV Battery Stack 2 Circuit Resistance Out of Range | ||
P33E01B | Hybrid/EV Battery Stack 1 Circuit Resistance Above Threshold | ||
P33E11B | Hybrid/EV Battery Stack 2 Circuit Resistance Above Threshold | ||
P33EC16 | (Extreme) Hybrid/EV Battery Stack 1 Cell Circuit Voltage Below Threshold | ||
P33ED16 | (Extreme) Hybrid/EV Battery Stack 2 Cell Circuit Voltage Below Threshold | ||
U029387 | Lost Communication with Hybrid/EV Powertrain Control Module Missing Message | ||
U115087 | Lost Communication with Hybrid Powertrain Control Module (Hybrid/EV Battery Local Bus) Missing Message |
Malfunction Content | System |
Relevant DTC | |
---|---|---|---|
Microcomputer malfunction |
Motor generator control system |
P0A1A47 | Generator Control Module Watchdog / Safety MC Failure |
P0A1A49 | Generator Control Module Internal Electronic Failure | ||
P0A1B1F | Generator Control Module Circuit Intermittent | ||
P0A1B47 | Drive Motor "A" Control Module Watchdog / Safety MC Failure | ||
P0A1C47 | Drive Motor "B" Control Module Watchdog / Safety MCU Failure | ||
P0A1C49 | Drive Motor "B" Control Module Internal Electronic Failure | ||
P1C2A1C | Generator A/D Converter Circuit Circuit Voltage Out of Range | ||
P1C2A49 | Generator A/D Converter Circuit Internal Electronic Failure | ||
P1C2A71 | Generator A/D Converter Circuit Actuator Stuck | ||
P1C2B1C | Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range | ||
P1C2B49 | Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure | ||
P1C2B71 | Drive Motor "A" Control Module A/D Converter Circuit Actuator Stuck | ||
P1C2C1C | Drive Motor "B" Control Module AD Converter Circuit Voltage Out of Range | ||
P1C2C49 | Drive Motor "B" Control Module AD Converter Internal Electronic Failure | ||
P1C2C71 | Drive Motor "B" Control Module A/D Converter Circuit Actuator Stuck | ||
P310A83 | Communication Error from Drive Motor "B" to Drive Motor "A" Value of Signal Protection Calculation Incorrect | ||
P310A86 | Communication Error from Drive Motor "B" to Drive Motor "A" Signal (Some Circuit Quantity, Reported via Serial Data) Invalid | ||
P310A87 | Communication Error from Drive Motor "B" to Drive Motor "A" Missing Message | ||
P310B83 | Communication Error from Drive Motor "A" to Drive Motor "B" Value of Signal Protection Calculation Incorrect | ||
P310B86 | Communication Error from Drive Motor "A" to Drive Motor "B" Signal (Some Circuit Quantity, Reported via Serial Data) Invalid | ||
P310B87 | Communication Error from Drive Motor "A" to Drive Motor "B" Missing Message | ||
P313383 | Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect | ||
P313386 | Communication Error from Generator to Drive Motor "A" Signal Invalid | ||
P313387 | Communication Error from Generator to Drive Motor "A" Missing Message | ||
P313483 | Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect | ||
P313486 | Communication Error from Drive Motor "A" to Generator Signal Invalid | ||
P313487 | Communication Error from Drive Motor "A" to Generator Missing Message | ||
P32BF83 | Lost Communication between Drive Motor "A" and "B" (Drive Motor "A") Value of Signal Protection Calculation Incorrect | ||
P32BF86 | Lost Communication between Drive Motor "A" and "B" (Drive Motor "A") Signal (Some Circuit Quantity, Reported via Serial Data) Invalid | ||
P32BF87 | Lost Communication between Drive Motor "A" and "B" (Drive Motor "A") Missing Message | ||
P32CF83 | Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Value of Signal Protection Calculation Incorrect | ||
P32CF86 | Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Signal (Some Circuit Quantity, Reported via Serial Data) Invalid | ||
P32CF87 | Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Missing Message | ||
Hybrid control system | P0A1B49 |
Drive Motor "A" Control Module Internal Electronic Failure | |
Power source circuit malfunction |
Motor generator control system | P06B01C |
Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
P06B31C | Drive Motor "B" Control Module Position Sensor REF Power Source Circuit Voltage Out of Range | ||
P06D61C | Generator Control Module Offset Power Circuit Voltage Out of Range | ||
P19F81C | Generator Control Module Offset Power Circuit Voltage Out of Range | ||
P19F91C | Drive Motor "B" Control Module Offset Power Circuit Voltage Out of Range | ||
P26DF1C | Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range | ||
Communication malfunction | Motor generator control system |
U11B387 | Lost Communication with Hybrid/EV Powertrain Control Module (ch5) Missing Message |
Hybrid control system | U117E87 |
Lost Communication with Drive Motor Control Module "A" (ch4) Missing Message | |
Sensor and actuator circuit malfunction |
Motor generator control system |
P0A3F16 | Drive Motor "A" Position Sensor Circuit Voltage Below Threshold |
P0A3F21 | Drive Motor "A" Position Sensor Signal Amplitude < Minimum | ||
P0A3F22 | Drive Motor "A" Position Sensor Signal Amplitude > Maximum | ||
P0A4516 | Drive Motor "B" Position Sensor Circuit Voltage Below Threshold | ||
P0A4521 | Drive Motor "B" Position Sensor Signal Amplitude < Minimum | ||
P0A4522 | Drive Motor "B" Position Sensor Signal Amplitude > Maximum | ||
P0A4B16 | Generator Position Sensor Circuit Voltage Below Threshold | ||
P0A4B21 | Generator Position Sensor Signal Amplitude < Minimum | ||
P0A4B22 | Generator Position Sensor Signal Amplitude > Maximum | ||
P0A6012 | Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery | ||
P0A6014 | Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open | ||
P0A601C | Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range | ||
P0A6312 | Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery | ||
P0A6314 | Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open | ||
P0A631C | Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range | ||
P0A6912 | Drive Motor "B" Phase V Current(High Resolution) Circuit Short to Battery | ||
P0A6914 | Drive Motor "B" Phase V Current(High Resolution) Circuit Short to Ground or Open | ||
P0A691C | Drive Motor "B" Phase V Current(High Resolution) Circuit Voltage Out of Range | ||
P0A6C12 | Drive Motor "B" Phase W Current(High Resolution) Circuit Short to Battery | ||
P0A6C14 | Drive Motor "B" Phase W Current(High Resolution) Circuit Short to Ground or Open | ||
P0A6C1C | Drive Motor "B" Phase W Current(High Resolution) Circuit Voltage Out of Range | ||
P0BE512 | Drive Motor "A" Phase U Current Sensor Circuit Short to Battery | ||
P0BE514 | Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open | ||
P0BE528 | Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
P0BE912 | Drive Motor "A" Phase V Current Sensor Circuit Short to Battery | ||
P0BE914 | Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open | ||
P0BE928 | Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
P0BED12 | Drive Motor "A" Phase W Current Sensor Circuit Short to Battery | ||
P0BED14 | Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open | ||
P0BED28 | Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
P0BF112 | Drive Motor "B" Phase U Current Sensor Circuit Short to Battery | ||
P0BF114 | Drive Motor "B" Phase U Current Sensor Circuit Short to Ground or Open | ||
P0BF128 | Drive Motor "B" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
P0BF512 | Drive Motor "B" Phase V Current Sensor Circuit Short to Battery | ||
P0BF514 | Drive Motor "B" Phase V Current Sensor Circuit Short to Ground or Open | ||
P0BF528 | Drive Motor "B" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
P0BF912 | Drive Motor "B" Phase W Current Sensor Circuit Short to Battery | ||
P0BF914 | Drive Motor "B" Phase W Current Sensor Circuit Short to Ground or Open | ||
P0BF928 | Drive Motor "B" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
P0BFD62 | Drive Motor "A" Phase U-V-W Current Sensor Signal Compare Failure | ||
P0BFE62 | Drive Motor "B" Phase U-V-W Current Sensor Signal Compare Failure | ||
P0C5013 | Drive Motor "A" Position Sensor Circuit "A" Circuit Open | ||
P0C5016 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold | ||
P0C5017 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold | ||
P0C5513 | Drive Motor "B" Position Sensor Circuit "A" Circuit Open | ||
P0C5516 | Drive Motor "B" Position Sensor Circuit "A" Circuit Voltage Below Threshold | ||
P0C5517 | Drive Motor "B" Position Sensor Circuit "A" Circuit Voltage Above Threshold | ||
P0C5A13 | Drive Motor "A" Position Sensor Circuit "B" Circuit Open | ||
P0C5A16 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold | ||
P0C5A17 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold | ||
P0C5F13 | Drive Motor "B" Position Sensor Circuit "B" Circuit Open | ||
P0C5F16 | Drive Motor "B" Position Sensor Circuit "B" Circuit Voltage Below Threshold | ||
P0C5F17 | Drive Motor "B" Position Sensor Circuit "B" Circuit Voltage Above Threshold | ||
P0C6413 | Generator Position Sensor Circuit "A" Circuit Open | ||
P0C6416 | Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold | ||
P0C6417 | Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold | ||
P0C6913 | Generator Position Sensor Circuit "B" Circuit Open | ||
P0C6916 | Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold | ||
P0C6917 | Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold | ||
P0D2D16 | Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold | ||
P0D2D17 | Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold | ||
P0DFA62 | Generator Phase U-V-W Current Sensor Signal Compare Failure | ||
P0E0012 | Generator Phase U Current Sensor Circuit Short to Battery | ||
P0E0014 | Generator Phase U Current Sensor Circuit Short to Ground or Open | ||
P0E0028 | Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
P0E0412 | Generator Phase V Current Sensor Circuit Short to Battery | ||
P0E0414 | Generator Phase V Current Sensor Circuit Short to Ground or Open | ||
P0E0428 | Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
P0E0812 | Generator Phase W Current Sensor Circuit Short to Battery | ||
P0E0814 | Generator Phase W Current Sensor Circuit Short to Ground or Open | ||
P0E0828 | Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
P0E3116 | DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Below Threshold | ||
P0E3117 | DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Above Threshold | ||
P0E5111 | DC/DC Converter Current Sensor Circuit Short to Ground | ||
P0E5115 | DC/DC Converter Current Sensor Circuit Short to Battery or Open | ||
P0E5128 | DC/DC Converter Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
P0E512A | DC/DC Converter Current Sensor Signal Stuck In Range | ||
P1CAC49 | Generator Position Sensor Internal Electronic Failure | ||
P1CAD49 | Drive Motor "A" Position Sensor Internal Electronic Failure | ||
P1CAE49 | Drive Motor "B" Position Sensor Internal Electronic Failure | ||
P1CAF38 | Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect | ||
P1CB038 | Drive Motor "A" Position Sensor REF Signal Frequency Incorrect | ||
P1CB138 | Drive Motor "B" Position Sensor REF Signal Frequency Incorrect | ||
P1CFF62 | Hybrid/EV Battery Current/DC/DC Converter Current Signal Compare Failure | ||
Hybrid control system | P0C7600 |
Hybrid/EV Battery System Discharge Time Too Long | |
P0D2D1C | Drive Motor "A" Inverter Voltage Sensor Voltage Out of Range | ||
P0E311C | Boosting Converter Voltage Sensor "A" Voltage Out of Range | ||
System malfunction |
Motor generator control system | P0A9000 |
Drive Motor "A" Performance |
P0A9100 | Drive Motor "B" Performance | ||
P0A9200 | Hybrid/EV Generator Performance | ||
P0A949E | DC/DC Converter Stuck On | ||
P0C021D | Drive Motor "B" System Circuit Current Out of Range | ||
P0C1A00 | Drive Motor "B" Execution Torque Performance | ||
P0CA300 | DC/DC Converter Step Up Voltage Performance | ||
P0D3319 | DC/DC Converter Circuit Current Above Threshold | ||
P0E5717 | DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Above Threshold | ||
P0E7100 | Generator Execution Torque Performance | ||
P1CA51D | Hybrid/EV Generator Circuit Current Out of Range | ||
P1CB59E | DC/DC Converter Voltage Sensor "A" (VL) Stuck On | ||
P314F1F | DC/DC Converter Voltage Sensor "A" (VL) Circuit Intermittent | ||
P31531D | DC/DC Converter Current Sensor Circuit Current Out of Range | ||
Hybrid control system | P0A9300 |
Inverter "A" Cooling System Performance | |
P0AA649 | Hybrid/EV Battery Voltage System Isolation Internal Electronic Failure | ||
P0C7396 | Motor Electronics Coolant Pump "A" Component Internal Failure | ||
P314A31 | Motor Electronics Coolant Pump "A" No Signal |
System | Relevant DTC | |
---|---|---|
Motor generator control system | P06B31F |
Drive Motor "B" Control Module Position Sensor REF Power Source Circuit Intermittent |
P0A3F1F | Drive Motor "A" Position Sensor Circuit Intermittent | |
P0A451F | Drive Motor "B" Position Sensor Circuit Intermittent | |
P0A4B1F | Generator Position Sensor Circuit Intermittent | |
P0A601F | Drive Motor "A" Phase V Current (High Resolution) Circuit Intermittent | |
P0A631F | Drive Motor "A" Phase W Current (High Resolution) Circuit Intermittent | |
P0A691F | Drive Motor "B" Phase V Current(High Resolution) Circuit Intermittent | |
P0A6C1F | Drive Motor "B" Phase W Current(High Resolution) Circuit Intermittent | |
P0BE51F | Drive Motor "A" Phase U Current Sensor Circuit Intermittent | |
P0BE91F | Drive Motor "A" Phase V Current Sensor Circuit Intermittent | |
P0BED1F | Drive Motor "A" Phase W Current Sensor Circuit Intermittent | |
P0C501F | Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent | |
P0C551F | Drive Motor "B" Position Sensor Circuit "A" Circuit Intermittent | |
P0C5A1F | Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent | |
P0C5F1F | Drive Motor "B" Position Sensor Circuit "B" Circuit Intermittent | |
P0C641F | Generator Position Sensor Circuit "A" Circuit Intermittent | |
P0C691F | Generator Position Sensor Circuit "B" Circuit Intermittent | |
P0D2D1F | Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Intermittent | |
P0E001F | Generator Phase U Current Sensor Circuit Intermittent | |
P0E041F | Generator Phase V Current Sensor Circuit Intermittent | |
P0E081F | Generator Phase W Current Sensor Circuit Intermittent | |
P0E311F | DC/DC Converter Voltage Sensor "A" (VL) Circuit Intermittent | |
P0E511F | DC/DC Converter Current Sensor Circuit Intermittent | |
P1C601F | Generator Control Module Position Sensor REF Power Source Circuit Intermittent | |
P1C621F | Generator Control Module Offset Power Circuit Intermittent | |
P1C641F | Generator Control Module Circuit Intermittent | |
P1C651F | Generator Control Module Circuit Intermittent | |
P1C661F | Drive Motor "B" Control Module Circuit Intermittent | |
P1C671F | Drive Motor "A" Phase U-V-W Current Sensor Circuit Intermittent | |
P1C681F | Drive Motor "B" Phase U-V-W Current Sensor Circuit Intermittent | |
P1C691F | Generator Phase U-V-W Current Sensor Circuit Intermittent | |
P26DF1F | Generator Control Module Position Sensor REF Power Source Circuit Intermittent | |
P310A1F | Communication Error from Drive Motor "B" to Drive Motor "A" Circuit Intermittent | |
P310B1F | Communication Error from Drive Motor "A" to Drive Motor "B" Circuit Intermittent | |
P31241F | Lost Communication between Drive Motor "A" and HV/EV ECU Circuit Intermittent | |
P32BF1F | Lost Communication between Drive Motor "A" and "B" (Drive Motor "A") Circuit Intermittent | |
P32CF1F | Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Circuit Intermittent |
PROCEDURE
1. | CHECK DTC OUTPUT (MOTOR GENERATOR) |
(a) Check for DTCs.
Powertrain > Motor Generator > Trouble Codes
Result | Proceed to |
---|---|
P0A7A73 is not output. |
A |
P0A7A73 is also output. |
B |
NOTICE:
(b) Turn the ignition switch off.
B | GO TO STEP 13 |
|
2. | CHECK FREEZE FRAME DATA AND DIAGNOSIS RELATED INFORMATION |
(a) Read the diagnosis related information and freeze frame data of DTC P0A7A9E or P1C5F19.
Powertrain > Motor Generator > Utility
Tester Display |
---|
Diagnosis Related Information |
Result | Proceed to |
---|---|
DTC U11B300 or 11B387 is listed in Diagnosis Related Information. |
A |
DTC U11B300 or 11B387 is not listed in Diagnosis Related Information and the value of freeze frame data item Emergency Shutdown Signal is ON. |
B |
Other than above |
C |
(b) Turn the ignition switch off.
A | GO TO DTC CHART (U11B300) |
B | GO TO DTC CHART (P321E9F) |
|
3. | CHECK FREEZE FRAME DATA |
(a) Read the freeze frame data of DTC P0A7A9E or P1C5F19.
Powertrain > Motor Generator > Trouble Codes
Result | Proceed to |
---|---|
Generator Inverter Temperature is 110°C or more |
A |
Other than above |
B |
(b) Turn the ignition switch off.
B | GO TO STEP 5 |
|
4. | CHECK COOLING SYSTEM |
Click here
NEXT | GO TO STEP 5 |
5. | CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR) |
Click here
Result | Proceed to |
---|---|
OK | A |
NG (The connector is not connected securely.) |
B |
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) |
C |
B | CONNECT SECURELY |
C | REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
6. | CHECK GENERATOR RESOLVER CIRCUIT |
Click here
|
7. | CHECK MOTOR RESOLVER CIRCUIT |
Click here
|
8. | CHECK REAR MOTOR RESOLVER CIRCUIT |
Click here
|
9. | CHECK GENERATOR HIGH-VOLTAGE CIRCUIT |
Click here
|
10. | CHECK MOTOR HIGH-VOLTAGE CIRCUIT |
Click here
|
11. | CHECK REAR MOTOR HIGH-VOLTAGE CIRCUIT |
Click here
|
12. | CHECK INVERTER LOW-VOLTAGE CIRCUIT |
Click here
HINT:
If the "Inverter Low-voltage Circuit" inspection results are normal, perform the next step.
NEXT | REPLACE INVERTER WITH CONVERTER ASSEMBLY |
13. | GO TO DTC CHART (P0A7A73) |
Click here
HINT:
After repairs have been completed, perform the next step.
NEXT | GO TO STEP 3 |