DIAGNOSTIC TROUBLE CODE CHART
Charging System
DTC No. |
Detection Item |
MIL |
Warning Indicate |
Note |
Link |
---|---|---|---|---|---|
P058A01 |
Battery Monitor Module General Electrical Failure |
Does not come on |
Charge warning light: Does not come on |
SAE Code: P058A |
|
P058A1E |
Battery Monitor Module Circuit Resistance Out of Range |
Does not come on |
Charge warning light does not come on |
SAE Code: P058A |
|
P058A46 |
Battery Monitor Module Calibration / Parameter Memory Failure |
Does not come on |
Charge warning light does not come on |
SAE Code: P058A |
|
P058B49 |
Battery Monitor Module Current Monitoring Performance Internal Electronic Failure |
Comes on |
Charge warning light does not come on |
SAE Code: P058B |
|
P058C01 |
Battery Monitor Module Temperature Monitoring Performance General Electrical Failure |
Does not come on |
Charge warning light does not come on |
SAE Code: P058C |
|
P058D01 |
Battery Monitor Module Voltage Monitoring Performance General Electrical Failure |
Does not come on |
Charge warning light does not come on |
SAE Code: P058D |
|
P062049 |
Generator Control Circuit Internal Electronic Failure |
Does not come on |
Charge warning light: Comes on |
SAE Code: P0620 |
|
P065C07 |
Generator "A" Mechanical Performance Mechanical Failure |
Does not come on |
Charge warning light: Comes on |
SAE Code: P065C |
|
P160200 |
Deterioration of Battery Low Capacity |
Does not come on |
Charge warning light: Does not come on |
SAE Code: P1602 |
|
P161A87 |
Lost Communication with Alternator Missing Message |
Does not come on |
Charge warning light: Does not come on |
SAE Code: P161A |
|
P162B87 |
Lost Communication with Battery Monitor Module Missing Message |
Comes on (For Mexico Models: Does not come on) |
Charge warning light: Does not come on |
SAE Code: P162B |
|
P16E818 |
Battery Monitor Module Current Monitoring Circuit Current Below Threshold |
Comes on |
Charge warning light does not come on |
SAE Code: P16EA |
|
P16E819 |
Battery Monitor Module Current Monitoring Circuit Current Above Threshold |
Comes on |
Charge warning light does not come on |
SAE Code: P16EB |
|
P16E81D |
Battery Monitor Module Current Monitoring Circuit Current Out of Range |
Comes on |
Charge warning light does not come on |