DATA LIST / ACTIVE TEST
DATA LIST
NOTICE:
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
HINT:
Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
(a) Read the Data List according to the display on the GTS.
Body Electrical > Air Conditioner > Data List
Tester Display | Measurement Item |
Range | Normal Condition |
Diagnostic Note |
---|---|---|---|---|
Total Distance Traveled |
Total distance traveled |
Min.: 0 Max.: 999999 |
Actual total distance displayed |
- |
Total Distance Traveled - Unit |
Total distance traveled unit |
km or mile | - |
- |
Ambient Temperature Sensor |
Thermistor assembly | Min.: -327.68°C (-557.82°F) Max.: 327.67°C (621.81°F) |
Actual ambient temperature displayed |
Thermistor assembly circuit malfunction |
Engine Coolant Temperature Sensor |
Engine coolant temperature sensor |
Min.: -327.68°C (-557.82°F) Max.: 327.67°C (621.81°F) |
Actual engine coolant temperature displayed |
|
Evaporator Fin Thermistor |
No. 1 cooler thermistor |
Min.: -327.68°C (-557.82°F) Max.: 327.67°C (621.81°F) |
Actual evaporator temperature displayed |
No. 1 cooler thermistor circuit malfunction |
Regulator Pressure Sensor |
Air conditioner pressure sensor |
Min.: -32768 kPa(gauge) Max.: 32767 kPa(gauge) |
Actual refrigerant pressure displayed |
|
Ambient Temperature Adjustment Value |
Adjusted ambient temperature |
Min.: -327.68°C (-557.82°F) Max.: 327.67°C (621.81°F) |
Adjust ambient temperature displayed |
Air conditioning amplifier assembly circuit malfunction |
Evaporator Target Temperature |
Evaporator target temperature |
Min.: -327.68°C (-557.82°F) Max.: 327.67°C (621.81°F) |
Evaporator target temperature displayed |
No. 1 cooler thermistor circuit malfunction
|
Air Inlet Damper Control Servo Motor Target Pulse |
No. 1 blower damper servo sub-assembly target pulse |
Min.: 128 Max.: 384 |
| No. 1 blower damper servo sub-assembly circuit malfunction |
Air Inlet Damper Control Servo Motor Actual Pulse |
No. 1 blower damper servo sub-assembly actual pulse |
Min.: 128 Max.: 384 |
| No. 1 blower damper servo sub-assembly circuit malfunction |
Front Air Mix Damper Control Servo Motor Target Pulse |
No. 1 air conditioning radiator damper servo sub-assembly target pulse |
Min.: 128 Max.: 384 |
| No. 1 air conditioning radiator damper servo sub-assembly circuit malfunction |
Front Air Mix Damper Control Servo Motor Actual Pulse |
No. 1 air conditioning radiator damper servo sub-assembly actual pulse |
Min.: 128 Max.: 384 |
| No. 1 air conditioning radiator damper servo sub-assembly circuit malfunction |
Front Air Outlet Damper Control Servo Motor Target Pulse |
No. 1 air conditioning radiator damper servo sub-assembly target pulse |
Min.: 128 Max.: 384 |
| No. 1 air conditioning radiator damper servo sub-assembly circuit malfunction |
Front Air Outlet Damper Control Servo Motor Actual Pulse |
No. 1 air conditioning radiator damper servo sub-assembly actual pulse |
Min.: 128 Max.: 384 |
| No. 1 air conditioning radiator damper servo sub-assembly circuit malfunction |
Solenoid Valve Control Current Value |
Solenoid valve control current |
Min.: 0 mA Max.: 1000 mA |
Value changes between 0 A and 0.997 A in accordance with solenoid valve operation |
- |
Refrigerant Gas Type |
Refrigerant gas type | R134a or Hfo1234yf |
Refrigerant gas type displayed |
- |
Refrigerant High Pressure History Count |
Refrigerant high pressure history |
Min.: 0 Max.: 255 |
Number of times refrigerant high pressure history stored displayed |
*1 |
Refrigerant Low Pressure History Count |
Refrigerant low pressure history |
Min.: 0 Max.: 255 |
Number of times refrigerant low pressure history stored displayed |
*1 |
Operation Limit Control History Count |
Operation limit control history |
Min.: 0 Max.: 255 |
Number of times operation limit control history stored displayed |
*2 |
Fan Speed Increment Control |
Fan speed increment control |
Short, Normal or Long | Customized value displayed |
- |
Outside Air Mode Auto Switch Function |
Outside air mode auto switch function |
OFF or ON | Customized value displayed |
- |
S-FLOW Control Auto Function |
S-FLOW control auto function |
OFF or ON | Customized value displayed |
- |
Evaporator Control |
Evaporator control | Manual or Automatic |
Customized value displayed |
- |
Ambient Temperature Adjustment |
Ambient temperature display adjustment function |
Min.: -3 °C Max.: 3 °C |
Customized value displayed |
- |
Refrigerant Shortage Check |
Refrigerant shortage check |
OFF or ON | Customized value displayed |
- |
Blower Level |
Blower motor speed level |
Min.: 0 Max.: 31 |
Displayed speed level increases in range between 0 and 31 as blower motor speed increases |
Blower motor with fan sub-assembly circuit malfunction |
A/C Driving Demand | A/C control cutoff signal |
OFF or ON | The ECM sends the air conditioning control cutoff signal displayed |
ECM circuit malfunction |
Click here
Click here
Tester Display | Measurement Item |
Range | Normal Condition |
Diagnostic Note |
---|---|---|---|---|
Coolant Temperature | Engine coolant temperature |
Min.: -40°C (-40°F) Max.: 140°C (284°F) |
75 to 100°C (167 to 212°F): After warming up |
This is the engine coolant temperature. HINT:
|
ACTIVE TEST
HINT:
Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
(a) Perform the Active Test according to the display on the GTS.
Body Electrical > Air Conditioner > Active Test
Tester Display | Measurement Item |
Control Range | Diagnostic Note |
---|---|---|---|
Blower Level | Blower motor with fan sub-assembly |
Min.: 0 Max.: 31 |
- |
A/C Driving Demand |
Air conditioning system |
OFF or ON | - |
Air Inlet Damper Control Servo Motor |
No. 1 blower damper servo sub-assembly pulse |
Min.: 128 Max.: 384 |
Operates between 220 and 256 pulses |
Front Air Mix Damper Control Servo Motor |
No. 1 air conditioning radiator damper servo sub-assembly pulse |
Min.: 128 Max.: 384 |
Operates between 255 to 347 pulses |
Front Air Outlet Damper Control Servo Motor |
No. 1 air conditioning radiator damper servo sub-assembly pulse |
Min.: 128 Max.: 384 |
Operates between 256 to 320 pulses |
Fr Control Rear Air Outlet Damper Servo Motor |
No. 2 air conditioning radiator damper servo sub-assembly pulse |
Min.: 128 Max.: 384 |
Operates between 250 to 297 pulses |