DATA LIST / ACTIVE TEST
DATA LIST
NOTICE:
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
HINT:
Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
(a) Perform the Active Test according to the display on the GTS.
Body Electrical > Power Distribution Box > Data List
Tester Display | Measurement Item |
Range | Normal Condition |
Diagnostic Note |
---|---|---|---|---|
Rear Defogger Input Signal |
Window defogger switch signal input condition |
OFF or ON | OFF: Rear window defogger switch is off ON: Rear window defogger switch is on |
- |
Rear Defogger Output Signal |
Window defogger output condition |
OFF or ON | OFF: Window defogger does not operate ON: Window defogger operates |
- |
Rear Defogger Output Current |
Window defogger current |
0 to 255.0 A | Approximately 27.0 A |
Window defogger current when output is on |
Rear Defogger Fuse Shut Off Status |
Window defogger fuse condition |
OFF or ON | OFF: Fuse shut off ON: Fuse not shut off |
- |
Rear Defogger Fuse Shut Off Count |
Window defogger fuse shut off times |
0 to 255 Times | 0 Times |
- |
Tester Display | Measurement Item |
Range | Normal Condition |
Diagnostic Note |
---|---|---|---|---|
Rear Defogger Relay | Window defogger operation condition |
ON or OFF | ON: Window defogger operates OFF: Window defogger does not operate |
- |
ACTIVE TEST
HINT:
Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
(a) Perform the Active Test according to the display on the GTS.
Body Electrical > Air Conditioner > Active Test
Tester Display | Measurement Item |
Control Range | Diagnostic Note |
---|---|---|---|
Rear Defogger Relay | Rear window defogger wire (Back door glass) |
OFF or ON | - |