Toyota Corolla Cross: Blower Motor does not Operate
DESCRIPTION
If air does not flow from the front registers after the blower switch on the air conditioning control assembly is operated, the following factors may be the cause.
Symptom | Factor |
Blower motor does not operate at all
- (Air does not blow from registers)
|
- Air conditioning amplifier assembly malfunction
- Blower motor with fan sub-assembly malfunction
- Warm-up control
- Engine coolant temperature sensor malfunction
- Harness or connector
|
PROCEDURE
1. |
CHECK AIR CONDITIONING SYSTEM (MANUAL MODE) |
(a) Operate the blower switch and check that the blower motor with fan sub-assembly can be operated manually.
OK:
The blower motor with fan sub-assembly operates normally.
NG |
| GO TO OTHER DIAGNOSIS PROCEDURE (Blower Motor Circuit) |
OK |
| |
(a) Read the Data List according to the display on the GTS.
Powertrain > Engine > Data List
Tester Display | Measurement Item |
Range | Normal Condition |
Diagnostic Note |
Coolant Temperature | Engine coolant temperature |
Min.: -40°C (-40°F), Max.: 140°C (284°F) |
75 to 100°C (167 to 212°F): After warming up |
This is the engine coolant temperature.
HINT:
- After warming up the engine, the engine coolant temperature will be 75 to 100°C (167 to 212°F).
- After a long soak, the engine coolant temperature, intake air temperature and ambient air temperature will be approximately equal.
- If the value is -40°C (-40°F), or higher than 135°C (275°F), the sensor circuit is open or shorted.
- Check if the engine overheats if the value indicated is higher than 135°C (275°F).
|
Powertrain > Engine > Data List
Tester Display |
Coolant Temperature |
OK:
After warming up the engine, the temperature value displayed is within the range specified in the normal condition column.
OK |
| REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY |
NG |
| GO TO COOLING SYSTEM |
READ NEXT:
DESCRIPTION If the airflow from the front registers is weak regardless of the blower speed setting displayed on the air conditioning control assembly, the following factors may be the cause.
Sym
DESCRIPTION If recirculation/fresh mode changes unintentionally and without permission, the following causes are possible.
Symptom Factor
Recirculation/fresh mode changes without
DESCRIPTION If the air inlet mode cannot be changed between recirculation/fresh or exhaust gas odors can be smelled even though recirculation mode is selected, the following factors may be the cause.
SEE MORE:
DESCRIPTION
Using the current from the TCM, the shift solenoid valve SLG controls the B1
brake when the shift lever is in R, and S1 synchronizer when the shift lever is
in P, N, D or M.
DTC No.
Detection Item
DTC Detection Condition
Trouble Area
DTC SUMMARY MALFUNCTION DESCRIPTION These DTCs indicate that the current sensor value is abnormal. The cause of this malfunction may be one of the following: Inverter internal malfunction
Inverter with converter assembly internal circuit malfunction
Inverter low-voltage circuit malfunctio